The pulse brew parameters (initial fill time, off times, and remaining on times) are entered using the following set- by-example process.

1.First set the brew volume using the standard procedure in Brew Volume Setup.

2.Position an empty container under the sprayhead. Allow the tank to finish refilling. Make sure that the READY lamp is on, or that the BREW LOCKOUT function is turned off.

3.Press and hold the OFF/ON button. The brew valve will turn on after 10 seconds. Release the button. This begins the initial on-timesetting. When the spray has continued for the desired time, momentarily press the OFF/ON button.

4.The spray is now stopped and the off time setting has begun. Press the OFF/ON button momentarily to end the off time.

5.The spray is now on again and the remaining on time setting has begun. Press the OFF/ON button momentarily at the end of the desired remaining on time.

6.The setup is now complete and the parameters are stored in memory. The spray will continue the off and on cycles until the brew volume of step 1 is complete. Pressing the OFF/ON button again will terminate the brewing cycle, with the parameters stored in memory.

7.If only a preinfusion is desired, i.e. an initial on time followed by one off period, use the same procedure, but stop after step 4 and allow the brew to finish the volume set in step 1. This will store the initial on time and off time in memory.

Procedure for Disabling Pulse Brew or Preinfusion:

1.Position an empty container under the sprayhead. Allow the tank to finish refilling. Make sure that the READY lamp is on, or that the BREW LOCKOUT function is turned off.

2.Press and hold the OFF/ON button. The brew valve will turn on after 10 seconds. Release the button.

3.Allow the spray to continue and press no buttons until spray stops. The pulse and preinfusion functions are now disabled.

NOTE: When the brewer has been set up for pulse or preinfusion, the adjustment of brew volume is done the same as always and has no effect on the pulse brew parameters. The pulsing is temporarily disabled while adjusting the brew volume and automatically returns during normal brewing.

Page 10

29319 091203

 

Image 10
Contents CEZ Cdbc Twin Contents IntroductionUser Notices Plumbing Requirements Electrical RequirementsElectrical Hook-Up Additional Warmer Switches ON/OFF SwitchBrew Switch Ready IndicatorInitial SET-UP CleaningCoffee Brewing CEZ Adjustments & Optional Settings Displaying Brew Temperature Cdbc Adjustments & Optional SettingsSetting Brew Temperature Setting Brew LockoutAdjusting Brew Volumes Pulse Brew Setup Procedure Cdbc Twin & Cdbcf Twin Troubleshooting Before troubleshooting this brewer, check for the followingProbable Cause TroubleshootingRefill Circuit Problem RemedyProblem Probable Cause Remedy Heating Circuit Problem Probable Cause Remedy Ings are taken 4b. Temperature Probe CEZ Remove the probe from3 of the J5 connector. At Control boardSet the temperature to 200F 4 of the J3 connector. At2b. Temperature Probe CEZ Remove the probe from Bilize. If temperature in tank isBrewing Circuit Problem Brew cycle will not startTroubleshooting Brewing Circuit Probable Cause Remedy Switch Move the two wires. Check forSupply and check wiring Holes are clear and unobDiagnostics Cause Things to CheckComponent Access ServiceContents Service PC Control Board Model Cdbc Disconnect the 11-pin connector from the control panelService PC Control Board Model CEZ Control Boards CEZService Switch Panel Model Cdbc Switch Panels CdbcService ON/OFF Switches Model CEZ Bottom switch terminal Service Brew Switch Start Model CEZMinals when the switch is released Service Dispense ValveLimit Thermostat Limit ThermostatsTank Heaters Tank HeaterService Tank Heaters Tank Heater WiringRefill Valve Check for continuity across the refill valve coil terminalsWarmer Elements Warmer ElementsSchematic Wiring Diagram CEZ Twin 0/6 Left Schematic Diagramwiring Twincdbc Schematic Wiring Diagram Cdbc Twin 2/2 Right
Related manuals
Manual 39 pages 50.34 Kb

TWIN specifications

The Bunn TWIN,ITB is a remarkable coffee brewing system designed for commercial use, aimed at establishments that require a high volume of coffee while maintaining superior quality. This innovative brewer stands out through its dual brewing capability, allowing users to brew two different types of coffee simultaneously. This feature is particularly beneficial for cafes, restaurants, and other food service locations where diverse customer preferences must be met efficiently.

One of the main features of the Bunn TWIN,ITB is its advanced brewing technology. The system utilizes Bunn's patented brewing process, ensuring optimal coffee extraction and flavor profile every time. It employs a digitally controlled brew timer and state-of-the-art heating elements, providing precise temperature control essential for achieving the ideal brew. This technology allows for consistent results, ensuring that each cup meets the high standards expected in a commercial setting.

The design of the TWIN,ITB is user-friendly and intuitive. It includes an easy-to-read LED display that simplifies programming and monitoring of the brewing process. This streamlined interface enables baristas to adjust settings quickly and efficiently, significantly reducing wait times for customers. Additionally, the unit's low-profile design enables it to fit seamlessly into various kitchen layouts and countertops, optimizing valuable space.

Durability and reliability are at the forefront of the Bunn TWIN,ITB's construction. Built with high-quality materials, the brewer is designed to withstand the rigors of intense daily use. Its stainless-steel finish not only provides a sleek and professional appearance but also makes it easy to clean and maintain, ensuring longevity and excellent performance throughout its lifespan.

Furthermore, the TWIN,ITB features an impressive water capacity with a built-in hot water tank. This allows users to brew large batches of coffee without interruption and offers instant hot water for tea, soups, or other hot beverages. The efficient brewing system utilizes pre-infusion technology, which saturates the coffee grounds before extraction, enhancing the overall flavor and aroma of the brewed coffee.

In summary, the Bunn TWIN,ITB is an exceptional choice for any commercial establishment looking to provide high-quality coffee efficiently. Its dual brewing capabilities, advanced technologies, user-friendly design, durability, and additional features make it a valuable addition to any coffee service operation. Whether busy mornings or afternoon rushes, this brewer ensures that every cup of coffee meets the high standards of taste and quality that customers expect.