FUNCTION LIST (Continued)

Circuit Board LED Indicators - JDF-4S and Late Model JDF-2S

LED #

LED Color

Illuminates:

 

 

 

1 Bath

Red

When bath temperature is above 34 degrees F.

 

 

 

 

 

Flashes slowly when compressor is in a 6 minute delay period.

 

 

 

 

 

Open bath thermistor circuit will flash #1 and #2 LED’s 1 time every 3

 

 

seconds. The compressor will not run under this condition.

 

 

 

 

 

Shorted bath thermistor circuit will flash #1 and #2 LED’s 2 times every 3

 

 

seconds. The compressor will not run under this condition.

 

 

 

2 Bath

Green

When bath temperature is below 34 degrees F.

 

 

 

3

Green

When the compressor should be ON.

 

 

 

4 Cabinet

Red

When the cabinet temperature is above 50 degrees F.

 

 

 

 

 

Flashes slowly when cabinet temperature exceeds 50 degrees F for 4

 

 

hours. Dispense functions are locked out under this condition. Power

 

 

down the dispenser to reset.

 

 

 

 

 

Flashes rapidly if dispense is attempted in lockout condition.

 

 

 

 

 

Open cabinet thermistor circuit will flash #4 and #5 LED’s 1 time every 3

 

 

seconds.

 

 

 

 

 

Shorted cabinet thermistor will turn #4 and #5 LED’s on steady.

 

 

*This mode disables the cabinet low temperature lockout fault.

5 Cabinet

Green

When cabinet temperature is below 50 degrees F.

 

 

 

4

 

1

5

 

2

 

 

3

 

FIG 19 JDF-4S

P3845

 

 

19

44744.2 110813

 

Image 19
Contents Phone 217 529-6601 FAX 217 JDF-2S JDF-4SBUNN-O-MATIC Commercial Product Warranty User Notices ContentsPlumbing Requirements Initial SET-UPCE Requirements Electrical RequirementsSecure the door cover using 5 screws provided Door Cover InstallationPlumbing Connections JDF-2S Plumbing Connections JDF-4S Plumbing HookupInitial Fill Initial Fill Operating Controls Refrigeration SwitchRefrigeration Switch Product Dispense Switch Mechanical Switch MachinesProgram Switch Product Dispense Switch Membrane Switch MachinesDispense Lockout Switch Dispense Lockout SwitchDispenser USE Portion Control Option Mechanical Switch MachinesPush and Hold Membrane Switch Machines Portion Control Option Membrane Switch MachinesTemperature LEDs JDF-2S Late Models Temperature LEDs JDF-4SDaily Rinse Procedure Cleaning & Preventive MaintenanceOpen dispenser door Cleaning Monthly Clean Condenser Coils and FilterWater Flow Testing and Adjustment Adjustment & Optional SettingsAmbient Concentrates Optional LoadingPriming Frozen Concentrates Ratio Target Dispenser Lockout Optional Cold Water Flow AdjustmentLED Color Illuminates Circuit Board LED Indicators JDF-2S Early ModelsFunction List LED #JDF-4S Remedy TroubleshootingProblem Probable CauseSpace around machine TroubleshootingCompressor ON/OFF switch Dirty condenser filter or fins RefrigerationProblem Probable Cause Remedy Water only Concentrate onlyWater pressure greater than Initial fill/setupNect fittings TrayProblem Probable Cause Coolant Schematic Diagram Models with LED Lited Doors Schematic Wiring Diagram JDF-2SRED BLK Models with Flourescent Lited DoorsBRN BLU EMI Schematic Wiring Diagram JDF-4SWire Shown.See Initial Fill Quick Setup Guide JDF-2S and JDF-4S JDF-2S shown