Bunn JDF-4S service manual Problem Probable Cause

Page 25

TROUBLESHOOTING (cont.)

PROBLEM

PROBABLE CAUSE

REMEDY

Unit is not working

1. Step-down transformer.

Check for 120/24 or 230/24 vac. If no 24vac reading, replace step-down transformer.

 

2. Main control board.

If 24 vac present and no LED’s lit,

 

 

replace control board..

Difficulty brixing and/or weak bev-

1. Product viscosity or too cold.

Thorough thaw of product before

erage

 

use (35° - 40°)

 

2. Low water pressure.

Maintain 20 psi or higher and a

 

 

minimum flow rate of 3 fl oz/sec.

 

3. High water pressure.

Over 100 psi, install a pressure

 

 

regulator and set to 50 psi.

 

4. Dispense valve adjustment set-

A) Perform 3 second water dispense

 

ting.

test. Factory setting is 1.0 oz/sec.

 

 

Acceptable water flow rate is .-0.8

 

 

to 1.5 oz/sec depending on the mix

 

 

ratio (4+1).

 

 

B) Adjust water to proper mix ratio.

 

 

Once water is set, adjust motor

 

 

speed to achieve brix %.

 

5. Brix ratio.

Check for proper brix ratio per prod-

 

 

uct using Total Dispense method

 

 

and or refractometer method.

Difficulty brixing and/or weak bev-

1. Pump tubing.

Inspect, clean, or replace tubing

erage

 

and pump rotor/rollers for ease of

 

 

rotation.

 

2. Use of portable water pump.

A) Follow plumbing requirements

 

 

for pressure and flow rate.

 

 

B) Source another portable pump

 

 

or water supply that meets require-

 

 

ments.

Difficulty brixing bag-in-box

Vacuum leak

Inspect all lines and connections

 

 

from bag-in-box connector to bottle

 

 

adapter assembly.

25

44744.2 062912

 

Image 25
Contents Phone 217 529-6601 FAX 217 JDF-2S JDF-4SBUNN-O-MATIC Commercial Product Warranty User Notices ContentsCE Requirements Initial SET-UPElectrical Requirements Plumbing RequirementsSecure the door cover using 5 screws provided Door Cover InstallationPlumbing Connections JDF-2S Plumbing Connections JDF-4S Plumbing HookupInitial Fill Initial Fill Refrigeration Switch Refrigeration SwitchProduct Dispense Switch Mechanical Switch Machines Operating ControlsDispense Lockout Switch Product Dispense Switch Membrane Switch MachinesDispense Lockout Switch Program SwitchPush and Hold Membrane Switch Machines Portion Control Option Mechanical Switch MachinesPortion Control Option Membrane Switch Machines Dispenser USETemperature LEDs JDF-2S Late Models Temperature LEDs JDF-4SDaily Rinse Procedure Cleaning & Preventive MaintenanceOpen dispenser door Cleaning Monthly Clean Condenser Coils and FilterWater Flow Testing and Adjustment Adjustment & Optional SettingsPriming LoadingFrozen Concentrates Ambient Concentrates OptionalRatio Target Dispenser Lockout Optional Cold Water Flow AdjustmentFunction List Circuit Board LED Indicators JDF-2S Early ModelsLED # LED Color IlluminatesJDF-4S Problem TroubleshootingProbable Cause RemedyCompressor ON/OFF switch Dirty condenser filter or fins TroubleshootingRefrigeration Space around machine Problem Probable Cause Remedy Water only Concentrate onlyNect fittings Initial fill/setupTray Water pressure greater thanProblem Probable Cause Coolant Schematic Diagram Models with LED Lited Doors Schematic Wiring Diagram JDF-2SRED BLK Models with Flourescent Lited DoorsBRN BLU EMI Schematic Wiring Diagram JDF-4SWire Shown.See Initial Fill Quick Setup Guide JDF-2S and JDF-4S JDF-2S shown
Related manuals