FUNCTION LIST
Circuit Board LED Indicators - JDF-2S (Early Models)
LED # | LED Color | Illuminates: |
|
|
|
1 | Green | When the compressor should be ON. |
|
|
|
2 Cabinet | Red | When the cabinet temperature is above 50 degrees F. |
|
|
|
|
| Flashes slowly when cabinet temperature exceeds 50 degrees F for 4 |
|
| hours. Dispense functions are locked out under this condition. Power |
|
| down the dispenser to reset. |
|
|
|
|
| Flashes rapidly if dispense is attempted in lockout condition. |
|
|
|
|
| Open cabinet thermistor circuit will flash #2 and #3 LED’s 1 time every 3 |
|
| seconds. |
|
|
|
|
| Shorted cabinet thermistor will turn #2 and #3 LED’s on steady. |
|
| *This mode disables the cabinet low temperature lockout fault. |
3 Cabinet | Green | When cabinet temperature is below 50 degrees F. |
|
|
|
4 Bath | Red | When bath temperature is above 34 degrees F. |
|
|
|
|
| Flashes slowly when compressor is in a 6 minute delay period. |
|
|
|
|
| Open bath thermistor circuit will flash #4 and #5 LED’s 1 time every 3 |
|
| seconds. The compressor will not run under this condition. |
|
|
|
|
| Shorted bath thermistor circuit will flash #4 and #5 LED’s 2 times every 3 |
|
| seconds. The compressor will not run under this condition. |
|
|
|
5 Bath | Green | When bath temperature is below 34 degrees F. |
|
|
|
| 1 |
2 | 3 |
4 | 5 |
FIG 18 | P3585 |
(Early Models) |
|
18 | 44744.2 110813 |
|