Bunn JDF-4S service manual Function List, Circuit Board LED Indicators JDF-2S Early Models, Led #

Page 18

FUNCTION LIST

Circuit Board LED Indicators - JDF-2S (Early Models)

LED #

LED Color

Illuminates:

 

 

 

1

Green

When the compressor should be ON.

 

 

 

2 Cabinet

Red

When the cabinet temperature is above 50 degrees F.

 

 

 

 

 

Flashes slowly when cabinet temperature exceeds 50 degrees F for 4

 

 

hours. Dispense functions are locked out under this condition. Power

 

 

down the dispenser to reset.

 

 

 

 

 

Flashes rapidly if dispense is attempted in lockout condition.

 

 

 

 

 

Open cabinet thermistor circuit will flash #2 and #3 LED’s 1 time every 3

 

 

seconds.

 

 

 

 

 

Shorted cabinet thermistor will turn #2 and #3 LED’s on steady.

 

 

*This mode disables the cabinet low temperature lockout fault.

3 Cabinet

Green

When cabinet temperature is below 50 degrees F.

 

 

 

4 Bath

Red

When bath temperature is above 34 degrees F.

 

 

 

 

 

Flashes slowly when compressor is in a 6 minute delay period.

 

 

 

 

 

Open bath thermistor circuit will flash #4 and #5 LED’s 1 time every 3

 

 

seconds. The compressor will not run under this condition.

 

 

 

 

 

Shorted bath thermistor circuit will flash #4 and #5 LED’s 2 times every 3

 

 

seconds. The compressor will not run under this condition.

 

 

 

5 Bath

Green

When bath temperature is below 34 degrees F.

 

 

 

 

1

2

3

4

5

FIG 18 JDF-2S

P3585

(Early Models)

 

18

44744.2 110813

 

Image 18
Contents JDF-2S JDF-4S Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Contents User NoticesElectrical Requirements Initial SET-UPCE Requirements Plumbing RequirementsDoor Cover Installation Secure the door cover using 5 screws providedPlumbing Hookup Plumbing Connections JDF-2S Plumbing Connections JDF-4SInitial Fill Initial Fill Product Dispense Switch Mechanical Switch Machines Refrigeration SwitchRefrigeration Switch Operating ControlsDispense Lockout Switch Product Dispense Switch Membrane Switch MachinesDispense Lockout Switch Program SwitchPortion Control Option Membrane Switch Machines Portion Control Option Mechanical Switch MachinesPush and Hold Membrane Switch Machines Dispenser USETemperature LEDs JDF-4S Temperature LEDs JDF-2S Late ModelsCleaning & Preventive Maintenance Daily Rinse ProcedureCleaning Monthly Clean Condenser Coils and Filter Open dispenser doorAdjustment & Optional Settings Water Flow Testing and Adjustment Frozen Concentrates Loading Priming Ambient Concentrates OptionalRatio Target Optional Cold Water Flow Adjustment Dispenser LockoutLED # Circuit Board LED Indicators JDF-2S Early ModelsFunction List LED Color IlluminatesJDF-4S Probable Cause TroubleshootingProblem RemedyRefrigeration TroubleshootingCompressor ON/OFF switch Dirty condenser filter or fins Space around machineProblem Probable Cause Remedy Concentrate only Water onlyTray Initial fill/setupNect fittings Water pressure greater thanProblem Probable Cause Coolant Schematic Diagram Schematic Wiring Diagram JDF-2S Models with LED Lited DoorsModels with Flourescent Lited Doors RED BLKSchematic Wiring Diagram JDF-4S BRN BLU EMIWire Quick Setup Guide JDF-2S and JDF-4S JDF-2S shown Shown.See Initial Fill