TROUBLESHOOTING (cont.) |
|
|
PROBLEM | PROBABLE CAUSE | REMEDY |
Dispense station not working | 1. Dispense Lockout switch set to | Place switch in ON position. |
| OFF position. |
|
| 2. Dispense switch failed | Check switch and harness for proper |
|
| continuity. |
All stations dispense concentrate | Main water supply | Check for ON position. |
only |
|
|
| Frozen bath | A) Compressor relay/contacts |
|
| shorted - replace relay. |
|
| B) Recirculating pump - replace or |
|
| check for kinked flex line. |
| Inlet water valve failed | A) Check for 120V or 230V power |
|
| when dispensing. If yes, replace |
|
| valve. If no, check harness for |
|
| proper continuity. Then replace |
|
| circuit board if needed. |