Carrier 16DF013-050 installation instructions Rigging 2-Piece Units, Sizes 16DF023-050

Page 6

Table 2 Ð Overall Dimensions, 16DF013-025

English

UNIT

 

 

OVERALL DIMENSIONS (ft-in.)

 

 

16DF

013

015

018

020

023

025

LENGTH

11-10

11-10

11-10

11-10

11-10

11-10

WIDTH

6-

7

6-

7

7-

8

7-

8

8-

3

8-

3

HEIGHT

7-

9

7-

9

7-

9

7-

9

8-

3

8-

3

 

 

 

 

 

SI

 

 

 

 

 

 

 

UNIT

 

 

OVERALL DIMENSIONS (mm)

 

 

16DF

013

015

018

020

023

025

LENGTH

3600

3600

3600

3600

3600

3600

WIDTH

1995

1995

2330

2330

2520

2520

HEIGHT

2350

2350

2350

2350

2500

2500

Table 3 Ð Overall Dimensions, 16DF028-050

English

UNIT

 

OVERALL DIMENSIONS (ft-in.)

 

16DF

028

032

036

040

045

050

LENGTH

15-4

15-4

15- 4

15- 4

15-4

15-4

WIDTH

9-4

9-4

9-10

9-10

10-6

10-6

HEIGHT

8-6

8-6

8-10

8-10

9-8

9-8

 

 

 

SI

 

 

 

UNIT

 

OVERALL DIMENSIONS (mm)

 

16DF

028

032

036

040

045

050

LENGTH

4660

4660

4660

4660

4660

4660

WIDTH

2850

2850

3000

3000

3200

3200

HEIGHT

2595

2595

2695

2695

2950

2950

RIGGING Ð The 2 pieces are the high-temperature generator- separator assembly and absorber-evaporator low-temperature generator assembly (Fig. 6).

1.Lift each assembly with cable, hooks, and shackles con- nected to the 4 lifting holes on each assembly. Lifting from other holes or locations can damage the machine.

2.Position and level the absorber-evaporator-assembly first. See Position and Level the Equipment section.

3.Move the generator-separator assembly into place beside the absorber-evaporator assembly.

4.Align connecting piping for generator-separator and absorber- evaporator assemblies. Make sure serial numbers corre- spond on both assemblies.

5.See Mounting the Burner section for burner rigging instructions.

Position and Level the Equipment Ð Isolation pads are not necessary for most installations. However, for cases where isolation pads are required, refer to Fig. 7 for typical installation.

Both 16DF machine assemblies must be level within 1¤4 in. per 20 ft (6.3 mm per 6 m), both lengthwise and di- agonally. To level the machine, proceed as follows:

1.Completely ®ll 50-ft (15 m) length of clear ¯exible tub- ing with water.

2.Use water gage and leveling reference points stamped on tube sheets to level machine.

3.Level machine with shims until requirements are met. If isolation assembly is used, shim under the soleplate. Be sure matching piping is in alignment.

Absorber-Evaporator Low-Temperature Generator Assembly

High-Temperature Generator-Separator Assembly

Fig. 6 Ð Rigging 2-Piece Units, Sizes 16DF023-050

NOTES:

1.Be sure only the machine base is on the isolation pad at each corner.

2.Shim under soleplate to level machine.

Fig. 7 Ð Typical Isolation Assembly

6

Image 6
Contents Installation Instructions Safety ConsiderationsContents IntroductionReceiving the Machine and Burner Rigging and Positioning Rigging 2-Piece Units16DF Views Typical Flamecutting and Welding Detail Rigging 2-Piece Units, Sizes 16DF023-050 Machine Assembly Assemble 2-Piece UnitsMounting the Burner Auxiliary Evacuation DeviceField Piping DescriptionPage Fusible Plug Drain Piping Fig Initial Solution and Refrigerant Charging Electrical ConnectionsInsulation and Paint

16DF013-050 specifications

The Carrier 16DF013-050 is an advanced air conditioning unit designed for superior performance and efficiency in residential and light commercial applications. Renowned for its reliable cooling capabilities, this model incorporates state-of-the-art technologies and features that enhance user comfort while minimizing energy consumption.

One of the standout characteristics of the Carrier 16DF013-050 is its high SEER (Seasonal Energy Efficiency Ratio) rating, which guarantees efficient cooling during the peak summer months. This unit is designed to operate at optimal efficiency, thereby reducing energy bills and providing substantial savings over time. Its innovative design minimizes energy use while delivering consistent comfort throughout the space.

The Carrier 16DF013-050 utilizes advanced scroll compressor technology, which ensures quiet operation and reduces vibrations, enhancing overall durability. This technology allows the unit to effectively modulate its cooling output according to demand, ensuring that the environment remains comfortable without wasting energy. Additionally, the unit is equipped with advanced diagnostics that make it easier for technicians to identify any maintenance issues promptly, reducing downtime and repair costs.

Another notable feature of this model is the inclusion of Carrier’s proprietary Infinity® control system, which provides users with the ability to manage their indoor climate through a user-friendly interface. The system enables remote control capabilities via smartphone apps, allowing for seamless integration into smart home systems. This means users can monitor and adjust their air conditioning settings even when they are not at home, ensuring optimal comfort at all times.

Durability is another hallmark of the Carrier 16DF013-050. The unit is built with high-quality materials that withstand harsh weather conditions, ensuring longevity and reliable operation. The cabinet is galvanized and powder-coated, providing an added layer of protection against rust and corrosion.

The Carrier 16DF013-050 is also designed with eco-conscious considerations in mind, utilizing R-410A refrigerant, which is less harmful to the environment compared to older refrigerants. This aligns with Carrier’s commitment to sustainability and energy efficiency.

In summary, the Carrier 16DF013-050 is an exemplary model in the realm of air conditioning systems. With its high efficiency, state-of-the-art compressor technology, advanced control options, and eco-friendly features, it offers an excellent solution for maintaining comfortable indoor climates while being mindful of energy consumption and environmental impact.