FRYER TROUBLESHOOTING GUIDE
All service (repairs or part replacement) must be performed by a qualified Service Agency.
PROBLEM | CAUSE |
|
| REMEDY | ||
|
|
|
|
|
| |
Pilot flame does not | 1. Dirty/sooty pilot burner. |
| 1. Clean the pilot burner. Perform | |||
stay lighted. |
|
|
|
| the Lighting Procedure. | |
| 2. Low gas supply pressure [less than 6” |
| 2. Measure the gas supply pres- | |||
| W.C. for natural gas (11” W.C. for pro- |
|
| sure. | ||
| pane) when all other |
|
| Contact your local gas supplier | ||
| ment is operating.]. |
|
| to obtain adequate gas supply | ||
|
|
|
|
| volume and pressure. | |
| 3. Pilot flame too small to heat thermo pile. |
| 3. Adjust the pilot valve (part of | |||
|
|
|
|
| the gas safety valve) to in- | |
|
|
|
|
| crease the flame size: Un- | |
|
|
|
|
| screw and retain the large | |
|
|
|
|
| threaded cover; turn the pilot | |
|
|
|
|
| valve adjustment screw two | |
|
|
|
|
| turns counterclockwise; | |
|
|
|
|
| reinstall the threaded cover. | |
| 4. Pilot flame ‘wavering’ (being blown about |
| 4. Block or redirect the draft, to | |||
| by a draft). |
|
| keep the flame burning steadily. | ||
| 5. Improper thermopile output voltage (must |
| 5. Replace the thermopile. | |||
| be at least 180 millivolts, measured at the |
|
|
|
| |
| thermocouple junction block). |
|
|
|
| |
| 6. |
| 6. Check for, and repair, any dam- | |||
| the gas. |
|
| aged | ||
|
|
|
|
| ing. Otherwise, test the high- | |
|
|
|
|
| limit thermostat by bypassing | |
|
|
|
|
| the | |
|
|
|
|
| and blue wires) at the gas con- | |
|
|
|
|
| trol valve with a jumper wire. | |
|
|
|
|
| Next, perform the Lighting Pro- | |
|
|
|
|
| cedure, to check whether the | |
|
|
|
|
| pilot flame lights. If the pilot | |
|
|
|
|
| flame lights and stays lit, the | |
|
|
|
|
| ||
|
|
|
|
| and must be replaced. | |
|
|
|
|
|
|
|
|
|
| ! | CAUTION: DO NOT return |
| |
|
|
|
|
| the fryer to normal operation |
|
|
|
|
|
| with its |
|
|
|
|
|
| bypassed. |
|
|
|
|
|
|
| |
| 7. Gas control valve has failed. |
| 7. Replace the gas control valve. | |||
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
16