Anetsberger Brothers SLG40 warranty Fryer Troubleshooting Guide, Problem Cause Remedy

Page 16

FRYER TROUBLESHOOTING GUIDE

All service (repairs or part replacement) must be performed by a qualified Service Agency.

PROBLEM

CAUSE

 

 

REMEDY

 

 

 

 

 

 

Pilot flame does not

1. Dirty/sooty pilot burner.

 

1. Clean the pilot burner. Perform

stay lighted.

 

 

 

 

the Lighting Procedure.

 

2. Low gas supply pressure [less than 6

 

2. Measure the gas supply pres-

 

W.C. for natural gas (11W.C. for pro-

 

 

sure.

 

pane) when all other gas-powered equip-

 

 

Contact your local gas supplier

 

ment is operating.].

 

 

to obtain adequate gas supply

 

 

 

 

 

volume and pressure.

 

3. Pilot flame too small to heat thermo pile.

 

3. Adjust the pilot valve (part of

 

 

 

 

 

the gas safety valve) to in-

 

 

 

 

 

crease the flame size: Un-

 

 

 

 

 

screw and retain the large

 

 

 

 

 

threaded cover; turn the pilot

 

 

 

 

 

valve adjustment screw two

 

 

 

 

 

turns counterclockwise;

 

 

 

 

 

reinstall the threaded cover.

 

4. Pilot flame ‘wavering’ (being blown about

 

4. Block or redirect the draft, to

 

by a draft).

 

 

keep the flame burning steadily.

 

5. Improper thermopile output voltage (must

 

5. Replace the thermopile.

 

be at least 180 millivolts, measured at the

 

 

 

 

 

thermocouple junction block).

 

 

 

 

 

6. High-limit thermostat problem has shut off

 

6. Check for, and repair, any dam-

 

the gas.

 

 

aged high-limit thermostat wir-

 

 

 

 

 

ing. Otherwise, test the high-

 

 

 

 

 

limit thermostat by bypassing

 

 

 

 

 

the high-limit thermostat (black

 

 

 

 

 

and blue wires) at the gas con-

 

 

 

 

 

trol valve with a jumper wire.

 

 

 

 

 

Next, perform the Lighting Pro-

 

 

 

 

 

cedure, to check whether the

 

 

 

 

 

pilot flame lights. If the pilot

 

 

 

 

 

flame lights and stays lit, the

 

 

 

 

 

high-limit thermostat has failed

 

 

 

 

 

and must be replaced.

 

 

 

 

 

 

 

 

 

 

!

CAUTION: DO NOT return

 

 

 

 

 

 

the fryer to normal operation

 

 

 

 

 

 

with its high-limit thermostat

 

 

 

 

 

 

bypassed.

 

 

 

 

 

 

 

 

7. Gas control valve has failed.

 

7. Replace the gas control valve.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

Image 16
Contents Fryer Contents Fryer GAS Supply Specifications Shipping Container InspectionFryer Electrical Specifications Code RequirementsFryer Model SLG40 Site Installation Requirements Code RequirementsInstallation Requirements Fryer Restraining Device Installation InstructionsLEG Installation Instructions Installation RequirementsLEG Leveling Instructions Caster Installation Instructions Caster Leveling INSTRUC- TionsGAS Connection Instructions Caster Leveling InstructionsFryer Operation Recommendations Fryer Operating Instructions Fryer Preparation for USEShutdown Procedure Lighting ProcedureFryer Operating Instructions Recommended Frying Time for Popular Fried Foods TimeDaily Cleaning Procedure Monthly Maintenance Instructions Fryer Troubleshooting Guide Problem Cause RemedyFryer Troubleshooting Guide Problem CauseIgnite Fryer Troubleshooting Guide Limited Warranty