Anetsberger Brothers SLG40 warranty Fryer Electrical Specifications, Code Requirements

Page 4

FRYER ELECTRICAL SPECIFICATIONS

The ANETS Fryer Model SLG40 requires no external electric power source.

Figure 1 is the wiring diagram of an ANETS SLG40 Fryer.

Figure 1. Fryer Model SLG40 Wiring Diagram

CODE REQUIREMENTS

IMPORTANT: Read the Code Requirements and ALL installation instructions carefully, before starting the installation. Contact the fac- tory (800/ 837-2638) if any problems or ques- tions arise.

The fryer installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition); the Natural Gas Installation Code, CAN/ CGA-B149.1 (latest edition); or the Propane Gas Installation Code, CAN/CGA-B149.2 (latest edition), as applicable, including:

a.Disconnect the fryer and its individual shutoff valve from the gas supply piping system during any pressure testing of the gas supply system at test pressures in excess of ½ psig (3.45 kPa).

b.Isolate the fryer from the gas supply piping system during any pressure testing of the gas

supply system at test pressures equal to or less than ½ psig (3.45 kPa).

c.For fryers utilizing floor casters, the fryer instal- lation shall be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 (latest edition) or CAN/CGA 6.16 (latest edition), and a quick-disconnect device that complies with the Standard for Quick-Discon- nect Devices for Use with Gas Fuel, ANSI Z21.41 or CAN/CGA 1-6.9 (latest edition).

d.Restrict the movement of a caster-equipped fryer by using a limiting device (for example, a cable attached both to the fryer and to a fix- ture attached to the site structure) to avoid depending on the connector and the quick- disconnect device or its associated piping to limit fryer movement.

4

Image 4
Contents Fryer Contents Fryer GAS Supply Specifications Shipping Container InspectionFryer Electrical Specifications Code RequirementsFryer Model SLG40 Site Installation Requirements Code RequirementsInstallation Requirements Fryer Restraining Device Installation InstructionsLEG Installation Instructions Installation RequirementsLEG Leveling Instructions Caster Installation Instructions Caster Leveling INSTRUC- TionsGAS Connection Instructions Caster Leveling InstructionsFryer Operation Recommendations Fryer Operating Instructions Fryer Preparation for USEShutdown Procedure Lighting ProcedureFryer Operating Instructions Recommended Frying Time for Popular Fried Foods TimeDaily Cleaning Procedure Monthly Maintenance Instructions Fryer Troubleshooting Guide Problem Cause RemedyFryer Troubleshooting Guide Problem CauseIgnite Fryer Troubleshooting Guide Limited Warranty