Hoshizaki F-450MAH-C service manual Problem Possible Cause Remedy

Page 31

 

PROBLEM

 

POSSIBLE CAUSE

 

REMEDY

 

 

c)

Gear Motor Relay

1.

Coil winding opened.

1.

Replace.

 

 

 

 

 

 

 

 

 

 

 

 

2.

Bad contacts.

2.

Check for continuity

 

 

 

 

 

 

 

and replace.

 

 

d)

Control Timer

1.

Broken.

1.

Replace.

 

 

 

(Printed Circuit

 

 

 

 

 

 

 

Board)

 

 

 

 

 

 

e)

Gear Motor Protect

1.

Coil winding opened.

1.

Replace.

 

 

 

Relay

 

 

 

 

 

 

 

2.

Bad contacts.

2.

Check for continuity

 

 

 

 

 

 

 

 

 

 

 

and replace.

[4]

Water has been

a)

Gear Motor Fuse

1.

Blown Fuse.

1.

See 3. [3]. Find out the

 

supplied. Fan Motor

 

(Bussman GMD

 

 

 

cause and replace the

 

starts, but

 

1.5A)

 

 

 

Fuse.

 

Compressor and

 

 

 

 

 

 

 

Gear Motor will not

b)

Thermal Protector

2.

Bad contacts.

2.

Check for continuity

 

start.

 

(Gear Motor)

 

 

 

and replace.

[5]

Gear Motor starts,

a)

X2 Relay on Control

1.

Bad contacts.

1.

Check for continuity

 

but Compressor will

 

Timer

 

 

 

and replace.

 

not start or operates

 

 

2.

Coil winding opened.

2.

Replace Timer.

 

intermittently

 

 

 

 

 

 

 

b)

Starter

1.

Bad contacts.

1.

Check for continuity

 

 

 

 

 

 

 

 

 

and replace.

 

 

 

 

2.

Coil winding opened.

2.

Replace.

 

 

 

 

3.

Loose connections.

3.

Tighten.

 

 

c)

Start Capacitor or

1.

Defective.

1.

Replace.

 

 

 

Run Capacitor

 

 

 

 

 

 

d)

Compressor

1.

Loose connections.

1.

Tighten.

 

 

 

 

2.

Motor winding

2.

Replace.

 

 

 

 

 

opened or grounded.

 

 

 

 

 

 

3.

Motor Protector

3.

Find out the cause of

 

 

 

 

 

tripped.

 

overheat or

 

 

 

 

 

 

 

overcurrent.

 

 

e)

Power Supply

1.

Circuit Ampacity too

1.

Install a larger-sized

 

 

 

 

 

low.

 

conductor.

[6]

Gear Motor and

a)

Pressure Switch

1.

Dirty Air Filter or

1.

Clean.

 

Compressor start,

 

 

 

Condenser.

 

 

 

but operate

 

 

2.

Ambient temperature

2.

Get cooler.

 

intermittently

 

 

 

too warm.

 

 

 

 

 

 

3.

Fan not rotating.

3.

See "3. [1] a) Fan

 

 

 

 

 

 

 

Motor."

 

 

 

 

4.

Refrigerant

4.

Recharge.

 

 

 

 

 

overcharged.

 

 

 

 

 

 

5.

Refrigerant line or

5.

Clean and replace

 

 

 

 

 

components plugged.

 

drier.

 

 

 

 

 

 

 

 

 

 

 

 

6.

Bad contacts.

6.

Check for continuity

 

 

 

 

 

 

 

and replace.

 

 

 

 

7.

Loose connections.

7.

Tighten.

31

Image 31
Contents Modular Flaker Models 450MAH-C Hoshizaki AMERICA, INC Contents Water TEMP. F Specifications 1. F-450MAH450MAH-C II. General Information Construction Control Box Layout Timer Board Timer BoardSolid-State Control Sequence Part Code Page Page 450MAH Wiring Diagram450MAH-C Sequence of Electrical Circuit Page Compressor starts about 60 sec. after gear motor starts Page Low water except water-cooled model Page Page Page Page Page Timing Chart Gear Motor Relay OFF FAN Motor Flush ICE OFF Upper Lower Bottom ICE Production Performance Data883 891 898 IV. Service Diagnosis No Ice Production Problem Possible Cause Remedy Problem Possible Cause Remedy Low Ice Production Other Evacuation and Recharge R-404A Removal and Replacement of ComponentsService for Refrigerant Lines Refrigerant RecoveryBrazing Removal and Replacement of Compressor Removal and Replacement of Drier Removal and Replacement of Expansion Valve Auger Removal and Replacement of Evaporator AssemblyCutter Extruding HeadGear Motor Bearing-Lower and Mechanical SealRemoval and Replacement of Control Water Valve Removal and Replacement of Fan MotorRemoval and Replacement of Flush Water Valve Preparing the Icemaker for Long Storage VI. Cleaning and MaintenanceCleaning Solution Cleaning and Sanitizing InstructionsCleaning Procedure Sanitizing Procedure Initial Sanitizing SolutionSanitizing Procedure Final Page Maintenance Instructions