Hoshizaki DMC-750BWF, DCM-500BWF Storage BIN Following Cleaning Procedures for Water System

Page 30

[b] STORAGE BIN - Following Cleaning Procedures for Water System

1)Remove the Front Cover of the Storage Bin.

2)Remove the thumbscrews, first from the vertical plane and then from the horizontal plane of the Motor Brackets. Move the Agitating Motor(s) and the Dispensing Motor toward you. Then remove the Agitator(s) and the Dispensing Auger. See Fig. 13.

Note: Models DCM-750BAF and BWF are provided with two Agitators, and models DCM-500BAF and BWF with one Agitator.

Fig. 13

3)Remove the Bin Control Bracket Assembly. See Fig. 14

4)Remove the Snap Pin, the Shaft and the Activator.

5)Remove the thumbscrews, the Spout-Bin and the Spout Gasket-Bin. See Fig 15. For models DCM-750BAF and BWF, remove the Ice Guide, Drain Pipe Holder and Drain Pipe in the Storage Bin as well.

Fig. 14

Fig. 15

30

Image 30 Contents
DCM-500BAF DCM-500BWF DCM-750BAF DCM-750BWF Hoshizaki AMERICA, INC Contents Specifications Nameplate Rating Model Number DCM-500BWF Serial Number AC Supply Voltage Model Number DCM-750BAF Serial Number AC Supply Voltage Model Number DCM-750BWF Serial Number AC Supply Voltage DIMENSIONS/CONNECTIONS DCM-500BWF DCM-750BAF DCM-750BWF II. General Information Construction Operation How it works HOW to Remove Panels See Fig SET UP LocationCabinet Stand Dimensions with DCM-500BAF on SD-450 Dimensions with DCM-750BAF on SD-700 Electrical Connection See Fig Water Supply and Drain Connections See Air Cooled Model Final Check List Start UP See Fig Page Controls and Adjustments Portion Control Preparing the Icemaker for Long Storage See Page Cleaning and Maintenance Instructions Cleaning InstructionsPage Storage BIN Following Cleaning Procedures for Water System Page Maintenance Page Hoshizaki