8)Allow the icemaker to sit for about 10 minutes before operation. If you placed a clamp on the reservoir hose in step 7, remove it before operation.

9)Plug the icemaker back in. Move the power switch to the "ON" position and replace the panels in their correct positions.

10)Move the control switch to the "ICE" position. Run the icemaker until it stops automatically.

11)Move the control switch to the "DRAIN" position, and wait about 15 minutes for the water system to drain.

12)After the water has drained, move the control switch to the "OFF" position. Remove the upper front, top and left side panels.

13)Move the power switch to the "OFF" postion. Unplug the icemaker from the electrical outlet.

14)Disconnect the ice transport hose from the spout, and pour fresh water into the ice transport hose to rinse out the solution and fill the evaporator and reservoir. Be careful not to overfill the reservoir. Reconnect the transport hose.

15)Plug the icemaker back in. Move the power switch to the "ON" position and replace the panels in their correct positions.

16)Move the control switch to the "ICE" position. Run the icemaker until it stops automatically.

17)Move the control switch to the "DRAIN" position, and wait about 15 minutes for the water system to drain.

Note: If you do not sanitize the icemaker, go to step 14 in "4. Sanitizing Procedure."

3. Sanitizing Solution

Dilute approximately 0.82 fl. oz. (25 ml) of a 5.25% sodium hypochlorite solution (chlorine bleach) with 1.6 gallons (6.0 l) of warm water.

4.Sanitizing Procedure - Following Cleaning Procedure

1)Move the control switch to the "OFF" position and remove the upper front, top and left side panels.

2)Move the power switch to the "OFF" position. Unplug the icemaker from the electrical outlet.

3)Disconnect the ice transport hose from the spout, and pour the sanitizing solution into the ice transport hose. Be careful not to overfill the reservoir. Reconnect the transport hose.

4)Plug the icemaker back in. Move the power switch to the "ON" position and replace the panels in their correct positions.

5)Allow the icemaker to sit for about 10 minutes before operation, then move the control switch to the "ICE" position. Run the icemaker until it stops automatically.

6)Move the control switch to the "DRAIN" position, and wait about 15 minutes for the water system to drain.

7)Repeat steps 1 through 6 one time.

15

Image 15
Contents DT-400BAH-OS Hoshizaki AMERICA, INC Contents Hoshizaki ICE Maker Specifications Nameplate RatingDimensions / Connections See Fig How to Remove PanelsLocation SetupElectrical Connection Water Supply and Drain Connections Final Checklist Startup Page Portion Control Controls and AdjustmentsCleaning Procedure III. Cleaning and MaintenanceCleaning and Sanitizing Instructions Water System Cleaning SolutionSanitizing Procedure Following Cleaning Procedure Sanitizing SolutionPage Dispensing Components Cleaning and Sanitizing Procedure Cleaning and Sanitizing Instructions Dispensing ComponentsPage Condenser MaintenanceIcemaker and Storage Bin Air FilterPreparing the Icemaker for Long Storage Hoshizaki AMERICA, INC

DT-400BAH-OS specifications

The Hoshizaki DT-400BAH-OS is a versatile and robust undercounter refrigerator designed for commercial kitchens that require efficient food preservation while maximizing space. Known for its durability and performance, the DT-400BAH-OS is a valuable addition to any food service operation.

One of the standout features of the Hoshizaki DT-400BAH-OS is its impressive capacity. This undercounter refrigerator has a storage volume of 15.5 cubic feet, allowing ample space for ingredients and products. It is equipped with two adjustable shelves that can accommodate various storage needs, ensuring easy organization and accessibility.

This model is engineered with a stainless steel exterior and interior, offering a sleek and professional appearance while providing superior resistance to impacts, scratches, and rust. The durable construction ensures the longevity of the unit, making it a reliable choice for busy commercial settings.

Energy efficiency is another key characteristic of the Hoshizaki DT-400BAH-OS. It is designed with an efficient refrigeration system that uses R-290 refrigerant, which is environmentally friendly and complies with the latest regulations. The appliance operates quietly, making it suitable for front-of-house applications without disrupting staff or customers.

One of the innovative technologies featured in the Hoshizaki DT-400BAH-OS is the advanced cooling system, which maintains a consistent internal temperature range from 33°F to 39°F. This precision ensures that food items remain at optimal temperatures, maximizing freshness and safety.

The intuitive digital controls provide easy temperature monitoring and adjustment, allowing staff to quickly set the desired conditions. Additionally, the Hoshizaki DT-400BAH-OS includes a self-closing door with a stay-open feature at 90 degrees, facilitating effortless access while minimizing energy loss.

The unit is equipped with heavy-duty casters, making it mobile and easy to reposition as needed in a busy kitchen environment. Hoshizaki also places a strong emphasis on sanitation, ensuring that the DT-400BAH-OS complies with health codes and standards.

In conclusion, the Hoshizaki DT-400BAH-OS is a reliable undercounter refrigerator that combines durability, efficiency, and advanced technology to meet the demands of commercial kitchens. Whether you're storing ingredients, prepped items, or beverages, this appliance delivers consistent performance and ease of use, making it an indispensable tool for food service professionals.