Dynacord DPM 4000 manual 5.1.5 2-ChannelPaging Station Module NRS

Models: DPM 4000

1 86
Download 86 pages 44.01 Kb
Page 22
Image 22
5.1.5 2-Channel Paging Station Module (NRS 90215)

DEVICE DESCRIPTIONS

5.1.5 2-Channel Paging Station Module (NRS 90215)

This 2-channel audio input module is meant for the connection of DPC 4000 Series paging consoles. Each of the two input channels provide RJ-45 sockets allowing the connection of up to 4 paging stations plus paging station extensions per input. The microphone terminals are interconnected via 6-conductor parallel cables. The module can be installed in slot 1 and slot 2.

Next to the electronically balanced audio input, each input connector provides a serial RS-485 interface port and the power supply connection for the paging stations (see also: pin-assignment of the RJ-45 connector). The paging stations' power supply employs an electronic, programmable fuse, through which the maximum output current can be matched to meet actual system accommodations. This prevents the entire installation from malfunction, in case of short-circuit occurring in a single paging station only.

Input channels can be switched separately onto the monitor bus and you can monitor the audio signal via headphones or loudspeaker, either which is connected to the monitor output. Automatic pilot tone surveillance of the entire input stage is integrated as well. If necessary, retrofitting the audio inputs with transformers is possible.

Manual backgroundManual background DPM - PCI

DPC 4000 IN

A

DPC 4000 IN

B

90215

figure 5.7 2-channel paging station module

Note: When connecting several paging consoles to a single input, please keep in mind that line interruption or short-circuit can cause malfunction of several or even all paging stations of that specific line. In emergency alert installation, connecting security-related consoles to individual inputs is therefore of major importance.

Specifications:

description

DPM-PCI 2-channel paging station module, NRS 90215

connections

2 x RJ-45 sockets

audio

 

inputs

2, electronically balanced, transformers are optionally available

nominal input level

0 dBu / 775 mV

max. input level

+12 dBu / 3 V

input impedance

20 k￿

input balancing

> -30 dB

frequency response

20 Hz ... 20 kHz, ￿ 0.5 dB

S/N ratio

> 100 dB (A-weighted)

distortion

< 0.01 %

A/D-conversion

18-bit linear, Sigma-Delta

control interfaces

2 x RS-485 standard

power supply outputs for the DPC 4000 2, short-circuit-proof, electronically programmable fuses

supply voltage

24 V DC (21.6 ... 31.2 V DC)

nominal current

330 mA, 660 mA, 990 mA (adjustable, electronic fuse)

power consumption

2 W

operational temperature range

+5 ￿C ... +40 ￿C

dimensions W x H x D

37.5 x 81 x 248 mm

weight

152 g (220 g including 2 x NRS 90208)

extensions

NRS 90208 input transformer for 1 paging station input, order-No. 121 641

5-8

PROANNOUNCE System User Handbook 1.1

Page 22
Image 22
Dynacord DPM 4000 manual 5.1.5 2-ChannelPaging Station Module NRS