6.1PROANNOUNCE Hardware Configuration

6.1.1 DCS 400

When configuring and initially operating the DCS 400 system, please proceed as follows:

1. Cabling

Use the supplied flat-wire cable for connecting the relay modules DCS 408, DCS 409 in the desired order to the control module DCS 401. Mixed installation of relay modules is possible; numbering the relays is type-specific and has to be performed according to their sequence.

example:

 

Sequence

 

 

Module

 

 

Line relay No.

 

 

Control relay No.

 

 

 

 

 

 

 

 

 

 

1

 

 

DCS 408

 

1

-

5

 

 

 

 

 

2

 

 

DCS 408

 

6 - 10

 

 

 

 

 

3

 

 

DCS 409

 

 

 

 

 

 

1 - 5

 

 

4

 

 

DCS 408

 

11

-

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

DCS 409

 

 

 

 

 

 

6 - 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

DCS 408

 

16

-

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

...

 

...

 

 

 

...

 

 

...

 

Use the supplied flat-wire cable for connecting the logic input module DCS 412 to the control module DCS 401. Numbering the logic inputs has to be performed according to their sequence.

example:

 

Sequence

 

 

Module

 

 

Logic input No.

 

 

 

 

 

 

 

 

1

 

 

DCS 412

 

1 - 12

 

 

2

 

 

DCS 412

 

13 - 24

 

 

3

 

 

DCS 412

 

25 - 36

 

 

 

 

 

 

 

 

 

...

 

...

 

...

 

 

 

 

 

 

 

 

 

 

Use the supplied flat-wire cable for connecting the analog input / output modules DCS 416 to the control module DCS 401. Numbering the analog inputs and outputs has to be performed according to their sequence.

example:

 

Sequence

 

 

Module

 

 

Analog input No.

 

 

Analog output No.

 

 

 

 

 

 

 

 

 

 

1

 

 

DCS 416

 

1 - 8

 

1 - 8

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

DCS 416

 

9 - 16

 

9 - 16

 

Connect the control module DCS 401 via RJ-45 cable to the REMOTE CONTROL socket on the DPM 4000.

PROANNOUNCE System User Handbook 1.1