2. Voltage Supply

APPENDIX

2. Voltage Supply

Insert bridges serve to select the voltage supply connector of different modules. Please refer to the corresponding description of individual modules or to their block diagrams.

CAUTION: The maximum current handling capacity of RJ-45 connections and flat-wire cables has to be observed under all circumstances!

3. DCS 401 Addresses

Using the Dip switch S1, the addresses of all connected control modules DCS 401 have to be set to different numbers (addresses 0 - 7).

 

 

Dip switch S1

 

 

Address

1

2

3

4

 

5

6

 

OFF

OFF

OFF

OFF

 

OFF

OFF

0

ON

OFF

OFF

OFF

 

OFF

OFF

1

OFF

ON

OFF

OFF

 

OFF

OFF

2

ON

ON

OFF

OFF

 

OFF

OFF

3

OFF

OFF

ON

OFF

 

OFF

OFF

4

ON

OFF

ON

OFF

 

OFF

OFF

5

OFF

ON

ON

OFF

 

OFF

OFF

6

ON

ON

ON

OFF

 

OFF

OFF

7

4. Before initial operation

Connect a 24V source. Now, each DCS 401 control module verifies whether any local modules (DCS 408, DCS 409, DCS 412, DCS 416) are connected, and if so, how many. The red LED blinks when the initialization process has not been performed yet.

Only for DCS 401 control modules with software version previous to V1.1:Each DCS 401 control module is initialized by pressing the S2 button for approximately 3 seconds. Afterwards, the red LED has to light continuously signaling that initialization was successfully completed.

Launch netscan (menu communication / netscan within the PROANNOUNCE Designer software). Now, the DCS 401 modules are being initialized. Afterwards, the DPM 4000 runs a test verifying all addresses and recognizes the amount of DCS 401 control modules installed in the system. All components sharing the network are listed in the component list. This procedure takes approximately 20 seconds. Afterwards, the system is ready for operation.

6-2

PROANNOUNCE System User Handbook 1.1

Page 84