5.2.14 Cable Length

DEVICE DESCRIPTIONS

5.2.14 Cable Length

Depending on the utilized paging station model and amount, and in relation to minimal supply voltage and cable- diameter, different maximum cable lengths are possible. The following tabulations show some examples for cable-diameters of 0.6 mm and 0.8 mm and with supply voltages of 24 V, respectively of 21.6 V in emergency supply operation. For precise calculation, a calculation-chart running under MS-EXCEL 97 is provided.

A Single Paging Station On A Single DPM-Line:

Cable type

Paging console model

Cable length (m)

Cable length (m)

 

 

21.6 V emergency

24 V

 

 

supply

 

JY(St)Y 4x2x0,6

DPC4510/4106

230

395

 

DPC4520

225

385

 

DPC4550

220

375

JY(St)Y 4x2x0,8

DPC4510/4106

410

700

 

DPC4520

400

690

 

DPC4550

390

670

A Single Paging Station + Extension On A Single DPM-Line:

 

 

 

 

 

Cable type

Paging console model

Cable length (m)

Cable length(m)

 

 

21.6 V emergency

24 V

 

 

supply

 

JY(St)Y 4x2x0,6

DPC4510 + DPC4350

150

260

 

DPC4520 + DPC4350

150

255

 

DPC4550 + DPC4350

145

250

JY(St)Y 4x2x0,8

DPC4510 + DPC4350

270

460

 

DPC4520 + DPC4350

265

455

 

DPC4550 + DPC4350

260

450

Four Paging Stations DPC4550 (+ Extensions) On A Single DPM-Line:

 

 

 

 

 

Cable type

Paging console model

Cable length (m)

Cable length (m)

 

 

21.6 V emergency

24 V

 

 

supply

 

JY(St)Y 4x2x0,6

4 x DPC 4550

55

95

 

4 x DPC4550

25

40

 

+ 4 x DPC4350

 

 

JY(St)Y 4x2x0,8

4 x DPC 4550

95

165

 

4 x DPC4550

40

75

 

+ 4 x DPC4350

 

 