DEVICE DESCRIPTIONS
5.2.14 Cable Length
Depending on the utilized paging station model and amount, and in relation to minimal supply voltage and cable- diameter, different maximum cable lengths are possible. The following tabulations show some examples for
A Single Paging Station On A Single
Cable type | Paging console model | Cable length (m) | Cable length (m) |
|
| 21.6 V emergency | 24 V |
|
| supply |
|
JY(St)Y 4x2x0,6 | DPC4510/4106 | 230 | 395 |
| DPC4520 | 225 | 385 |
| DPC4550 | 220 | 375 |
JY(St)Y 4x2x0,8 | DPC4510/4106 | 410 | 700 |
| DPC4520 | 400 | 690 |
| DPC4550 | 390 | 670 |
A Single Paging Station + Extension On A Single |
| ||
|
|
|
|
Cable type | Paging console model | Cable length (m) | Cable length(m) |
|
| 21.6 V emergency | 24 V |
|
| supply |
|
JY(St)Y 4x2x0,6 | DPC4510 + DPC4350 | 150 | 260 |
| DPC4520 + DPC4350 | 150 | 255 |
| DPC4550 + DPC4350 | 145 | 250 |
JY(St)Y 4x2x0,8 | DPC4510 + DPC4350 | 270 | 460 |
| DPC4520 + DPC4350 | 265 | 455 |
| DPC4550 + DPC4350 | 260 | 450 |
Four Paging Stations DPC4550 (+ Extensions) On A Single |
| ||
|
|
|
|
Cable type | Paging console model | Cable length (m) | Cable length (m) |
|
| 21.6 V emergency | 24 V |
|
| supply |
|
JY(St)Y 4x2x0,6 | 4 x DPC 4550 | 55 | 95 |
| 4 x DPC4550 | 25 | 40 |
| + 4 x DPC4350 |
|
|
JY(St)Y 4x2x0,8 | 4 x DPC 4550 | 95 | 165 |
| 4 x DPC4550 | 40 | 75 |
| + 4 x DPC4350 |
|
|
PROANNOUNCE System User Handbook 1.1 |