Dynacord DPM 4000 manual DCS 420 PROANNOUNCE MONITOR MANAGER, Installation Note

Models: DPM 4000

1 86
Download 86 pages 44.01 Kb
Page 79
Image 79
5.4.7 DCS 420 PROANNOUNCE MONITOR MANAGER

DEVICE DESCRIPTIONS

5.4.7 DCS 420 PROANNOUNCE MONITOR MANAGER

This monitor module (2 HU) is for mounting in PA-system rack-shelves. It is used for acoustically and optically monitoring power amplifier outputs (monitoring) as well as for pre-listening to DPM 4000 input signals in a PROANNOUNCE system installation. The DCS 401 controller controls the DCS 420.

Features

￿Loudspeaker 1W

￿6.3 mm stereo phone-type headphones jack

￿3-digit 7-segment display for source selection and volume setting

￿LED-bar graph meter instrument for monitoring and setting audio levels

￿Input transformers allow galvanic separation of the audio signal path

￿Detachable mounting plate for installing different connectors of the PA-central unit

￿Selector switch for selecting external or internal (from the DCS401) supply voltage sources

Installation Note

Mounting the module and establishing the connections are solely admissible when performed in accordance to VDE 0100 and EN 60065 regulations.

Specifications:

 

Operating voltage

24V DC, -10 / +30%

Operating current

250 mA (max)

Standby operating current (dark)

75 mA

Operating temperature range

+5° C ... +40° C

Dimensions (W x H x D) 19" 2HU

483 x 88 x 103 mm

Weight

2.1 kg

Audio input:

 

Input voltage (0 dB LED)

650 mV / -1.5 dBu

Max. input voltage

5.0 V / +16 dBu

Input impedance

2 k ohms

Audio output:

 

Monitor loudspeaker

1 W

Output voltage, phones max.

2 V / 8.2 dBu

Output impedance, phones

10 Ohm

Frequency response, phones jack

20Hz ... 20kHz, -3dB

S/N ratio

> 80 dB

Distortion

1% (1kHz)

PROANNOUNCE System User Handbook 1.1

5-65

Page 79
Image 79