DEVICE DESCRIPTIONS
5.4.3 DCS 408 RELAY MODULE 100 V
The module is to be mounted on the rear of a
Features
Five 100 V line relays, 2 switching contacts each, binding post per contact
5 output binding posts, each with 3 screws and label fields
5 relay
Configuration of the output distributor is performed through opening wire bridges
2 connectors for cascading up to 12 modules
2 binding posts for the connection of an external supply voltage source
Installation Note
For safety reasons, DCS 400 modules may only be installed in
Mounting the module and establishing the connections are solely admissible when performed in accordance to VDE 0100 and EN 60065 regulations.
DCS 408 relay module printed board assemblies need to be grounded at their fixing points (e.g. using a metal bolt).
The module has to be protected against dropping or splashing water.
Specifications:
Description | DCS 408 relay module 100 V |
Operating voltage | 24 V DC, |
Operating current, relay dropped | 5.2 mA .. 7,8 mA |
Operating current, relay dropped, at 24 V | 5.5 mA |
Operating current, all relays pulled | 87 mA .. 130 mA |
Operating current, all rel. pulled, at 24 V | 96 mA |
Relay contacts: |
|
Contact components | 2 changers/ 2 SPDT |
Contact material | AgNi 90/10 |
Contact load (ohmic load) | 2000 VA |
Contact current | 8 A |
Contact voltage | 100 V AC |
Operating temperature range | +5° C .. +40° C |
Dimensions (W x H x D) | 160 x 20 x 100 mm |
Weight | 200 g |
PROANNOUNCE System User Handbook 1.1 |