Dynacord DPM 4000 manual DCS 408 RELAY MODULE, Installation Note

Models: DPM 4000

1 86
Download 86 pages 44.01 Kb
Page 71
Image 71
5.4.3 DCS 408 RELAY MODULE 100 V

DEVICE DESCRIPTIONS

5.4.3 DCS 408 RELAY MODULE 100 V

The module is to be mounted on the rear of a PA-system rack-shelf or inside of a suitable distribution box. It is primarily used for switching 100 V loudspeaker lines. The relays can also be used for collective calls, obligatory reception, as E- relays and D-relays, or for general control purposes.

Features

￿Five 100 V line relays, 2 switching contacts each, binding post per contact

￿5 output binding posts, each with 3 screws and label fields

￿5 relay control-LED’s

￿Configuration of the output distributor is performed through opening wire bridges

￿2 connectors for cascading up to 12 modules

￿2 binding posts for the connection of an external supply voltage source

Installation Note

For safety reasons, DCS 400 modules may only be installed in rack-shelf systems or enclosures that are locked and may only be opened by means of a tool (e.g. screw-driver, special key, etc.).

Mounting the module and establishing the connections are solely admissible when performed in accordance to VDE 0100 and EN 60065 regulations.

DCS 408 relay module printed board assemblies need to be grounded at their fixing points (e.g. using a metal bolt).

The module has to be protected against dropping or splashing water.

Specifications:

Description

DCS 408 relay module 100 V

Operating voltage

24 V DC, -10 / +30 %

Operating current, relay dropped

5.2 mA .. 7,8 mA

Operating current, relay dropped, at 24 V

5.5 mA

Operating current, all relays pulled

87 mA .. 130 mA

Operating current, all rel. pulled, at 24 V

96 mA

Relay contacts:

 

Contact components

2 changers/ 2 SPDT

Contact material

AgNi 90/10

Contact load (ohmic load)

2000 VA

Contact current

8 A

Contact voltage

100 V AC

Operating temperature range

+5° C .. +40° C

Dimensions (W x H x D)

160 x 20 x 100 mm

Weight

200 g