DEVICE DESCRIPTIONS
5.1.11 8 I/O Control Module (NRS 90219)
This control module provides 8 floating control inputs and 7 floating logic level outputs (0 V, 24 V). An additional output provides pole change impulses for controlling slave system clocks. Contact is established via 4 x
The slave clock output (NU, OUT 1) is
The control outputs (OUT 2 - 8) are capable of switching voltages of either polarity and up to a maximum current of 1 A.
The control inputs (IN 1 - 8) are capable of handling voltages of either polarity between
figure 5.31 8 I/O control module
Note: The
Specifications:
description | |
connections | 4 x |
logic inputs | 8, floating via |
voltage when the input is LOW | UIN < 5 V |
voltage when the input is HIGH | UIN > 10 V |
maximum input voltage | UIN max = 31 V |
logic outputs | 7, floating via relay contacts |
contact capacity | 1 A / 24 V DC |
slave clock output | pole change impulse / turning impulse |
output voltage | 24 V DC |
maximum output current | 500 mA, electronically protected against overload |
power consumption | 3.2 W (12 W with the maximum amount of slave clocks connected) |
operational temperature range | +5 C ... +40 C |
dimensions W x H x D | 37.5 x 81 x 247 mm |
weight | 195 g |
PROANNOUNCE System User Handbook 1.1 |