DEVICE DESCRIPTIONS
5.4.4 DCS 409 CONTROL RELAY MODULE
The module is for mounting on the rear of
Features
5
Additional ground potential binding posts for each relay's primary and secondary end
5 relay
Configuration of the output distributor is performed through opening wire bridges
2 connectors for cascading up to 12 modules
2 binding posts for the connection of an external supply voltage source
Installation Note
Mounting the module and establishing the connections are solely admissible when performed in accordance to VDE 0100 and EN 60065 regulations.
DCS 409 control relay module printed board assemblies need to be grounded at their fixing points (e.g. using a metal bolt).
Specifications:
Description | DCS 409 control relay module |
Operating voltage | 24 V DC, |
Operating current, relay dropped | 5.2 mA .. 7.8 mA |
Operating current, relay dropped, at 24 V | 5.5 mA |
Operating current, all relays pulled | 55 mA .. 80 mA |
Operating current, all relays pulled, at 24 V | 60 mA |
Relay contacts: |
|
Contact components | 2 changers/ 2 SPDT |
Contact material | AgPd + 10µ Au |
Contact load (ohmic load) | 1 A / 24 V DC |
Contact current, maximum | 2 A |
Operating temperature range | +5° C .. +40° C |
Dimensions (W x H x D) | 160 x 17 x 100 mm |
Weight | 155 g |