DEVICE DESCRIPTIONS
5.4.2 DCS 401 CONTROL MODULE
The module is to be mounted on the rear of a
A single DCS 401 control module can host a maximum of 12 relay modules DCS 408 / DCS 409, five logic input modules DCS 412, two analog input / output modules DCS 416, and two rotary encoders. Relay modules are connected to the CN7 connector using the supplied
Features
Two
Galvanic separation of the
One connector each for relay modules, logic input modules and analog signal modules
One connector for two rotary encoders
Internal monitoring via watchdog circuitry
Line surveillance via polling
Two binding posts for the connection of an external supply voltage source
Service functions and testing software for all connected modules
Binary switch for address setting (0 - 7)
CAUTION: Each participant connected to the DPM 4000 remote port has to have an exclusive address. Each address can be used only once.
Installation Note
Mounting the module and establishing the connections are solely admissible when performed in accordance to VDE 0100 and EN 60065 regulations.
DCS 401 module printed board assemblies need to be grounded at their fixing points (e.g. using a metal bolt).
Specifications:
Description | DCS 401 control module |
Operating voltage | 24 V DC, |
Operating current | 25 mA .. 65 mA |
Operating current at 24 V | 35 mA |
Operating temperature range | +5° C .. +40° C |
Dimensions (W x H x D) | 160 x 25 x 100 mm |
Weight | 135 g |
PROANNOUNCE System User Handbook 1.1 |