DEVICE DESCRIPTIONS

Block Diagram:

 

 

 

 

 

 

 

ELECTRONIC

 

 

 

 

 

 

 

 

 

 

 

PROGRAMMABLE

 

 

+U24

 

 

 

 

 

 

 

 

FUSE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+12V

ANALOG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-12V

SUPPLY

 

 

 

 

 

 

 

 

 

 

 

 

 

DPC 4000

 

 

 

 

 

 

+5V

DIGITAL

 

 

IN A

 

 

 

 

 

 

 

SUPPLY

 

 

24V

 

 

 

 

 

 

 

 

 

 

RS-485

 

 

 

 

 

 

 

RX485

 

 

AUDIO

 

 

 

 

 

 

 

TX485

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NRS 90208

 

 

 

INTERNAL MONITOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MON A

 

 

PILOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

MCLK

 

 

 

 

 

 

 

PILOT A

 

 

BCLK

2 CHANNEL

 

 

 

 

 

 

 

 

 

 

DIGITAL

 

 

 

 

 

 

 

 

 

 

WCLK

 

 

 

 

 

 

 

D

 

 

AUDIO

 

 

 

 

 

 

 

 

 

 

DIN

 

 

 

 

+24V

 

 

MON B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JP1

1

3

 

 

 

 

4

SPI

 

 

 

 

2

4

 

PILOT B

 

 

BOARD

 

 

 

 

 

 

 

 

 

 

CONTROL

 

 

MIC/

 

 

 

 

 

 

 

 

 

 

 

 

MIC

 

 

 

 

 

 

LINE

 

 

 

GAIN

 

 

 

 

 

 

 

 

LINE

 

 

 

 

 

IN B

1

2

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

RES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NRS 90233

LIN

 

 

 

 

 

 

 

 

 

 

JP2

 

 

 

 

 

 

 

 

 

 

 

COMP

 

BOARD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STATUS

 

 

 

 

 

 

 

 

 

LINE JP1

& ID

 

 

 

 

 

 

 

 

 

MIC 5

6

 

 

 

 

 

 

 

 

 

COMPRESSOR /

 

 

 

 

 

 

 

 

 

 

 

LIMITER

 

 

 

 

 

 

 

figure 5.25

 

block diagram MIC/LINE + paging station module

 

 

 

 

Internal Settings:

1.MIC / LINE switching and sensitivity of the MIC / LINE input

The MIC / LINE input's internal PAD-switch (S1) allows switching the channels' sensitivity between microphone and line levels (30 dB). The GAIN-control on the module's front panel is provided to precisely adjust the input sensitivity (range 40 dB).

In addition, a MIC/LINE jumper (JP1, pins 5-6) is located on the printed board assembly, which allows correctly configuring the input. It is important to change the jumper accordingly (open = LINE, closed = MIC) when changing the MIC/LINE switch.

When shipped the switch S1 is pre-set to LINE and the jumper JP1 to its open position.

GAIN setting

MIC / LINE setting

MIC / LINE jumper

Input level

Left margin

MIC

Closed

-14 dBu

 

LINE

Open

+16 dBu

Center position

MIC

Closed

-28 dBu

 

LINE

Open

+2 dBu

Right margin

MIC

Closed

-54 dBu

 

LINE

Open

-24 dBu

2.Phantom power

Closing the pins 1-2 and 3-4 of the jumper JP1 offers the possibility to engage 24 V phantom power for microphones that are connected directly. When shipped, the jumper is factory pre-set to its “open” position (no phantom power).

3.Compressor / Limiter

The MIC / LINE input channel embodies a compressor / limiter circuit which can be incorporated into the signal path via jumper JP2 (position COMP). Normally, the compressor / limiter should be used to eliminate the risks of overdrive and clipping, when directly connecting a microphone. When shipped, the jumper is pre- set to its “Linear” position (LIN).

PROANNOUNCE System User Handbook 1.1

5-21