DEVICE DESCRIPTIONS
5.1.12 Flash Memory for Voice Recording/Playback (NRS 90205)
Internal Message Recorder
For using the internal message memory at least one voice message module NRS 90205 (121648) needs to be installed in the DPM 4000 and the
The Message Stacking Function is available together with the recorder.
Data: |
|
- number of internal texts (messages) | 25 |
- sampling frequency | 48kHz |
- sampling format | |
| |
- maximum recording time | |
| |
| |
| 8Bit, 10kHz, 4 message memory: 360 sec. (6 min.) |
- signal sources | DPM 4000 inputs IN1 – IN4 |
Instructions for retrofitting the Message Memory Extension (NRS 90205) into the DPM 4000
contents: | 1 printed board assembly 86237 |
1manual
1.Disconnect the appliance from any power supply.
2.Remove the cover (7 screws).
3.Insert the printed board 86237 on the main pcb 80249C
-Insert the printed board 86237 into an empty slot, starting with CN301, CN302, CN303 or CN 304.
4.Format the inserted memory boards (only possible using the PROANNOUNCE Designer software).
PROANNOUNCE System User Handbook 1.1 |