DEVICE DESCRIPTIONS
5.2.13 Optionally Available Accessories
Optional Alarm Key (NRS 90230)
The paging stations employ two empty slots for retrofitting optional alarm keys or
Brief description: | optional pushbutton or switch for retrofitting DPC | |
| as idling | opener. The pushbutton - switch function can be |
| configured on the hardware. |
|
Supplied with the NRS 90230: 1 switch – pushbutton, complete with label field and cover
1connection cord,
1resistor 10 k ohms
1lamp 6 volts
1selable cover
installation instructions:
1.Disconnect the paging console from the power supply.
2.Detach the bottom plate (6 to 8 screws, depending on the paging console model).
3.Prepare the installation site for the insertion:
Use a sharp, pinpoint tool (thick needle, pointed
Configure the switch to operate as switch or pushbutton.
CHANGE FROM: SWITCH to PUSHBUTTON
CAUTION: Install the switch so that the gap | figure 5.38 | optional pushbutton/ switch |
|
| |
for changing the switch’s operation points |
|
|
towards the TALK key. This allows for easy |
|
|
changing its function even after it has been |
|
|
inserted. |
|
|
Note: Please make sure to solder the cables after the switch has been installed. Otherwise it is virtually impossible to slide the
4.Adjust the switch and tighten it using the supplied milled nut.
5.Connect the cables and the resistor according to the circuit diagram on this page.
6.Please mind the sequence in which you connect the flat wire cables. The two outside wires 1(rt) and 4(gr) need to be soldered to the contacts of the lamp. The two inner wires 2(gr) and 3(gr) need to be soldered to contacts 1 and 2 of the switch. Polarity of either pair of wires is not critical.
7.Afterwards, you have to connect the
8.
9.Software configuration with the PROANNOUNCE Designer
figure 5.39 | circuit diagram pushbutton / switch |
PROANNOUNCE System User Handbook 1.1 |