DEVICE DESCRIPTIONS
5.1.10 2-Channel LINE Output Module (NRS 90218)
The output module is meant for the connection of power amplifiers with an input sensitivity of 0 dB or +6 dB. Two
The output channels can be switched separately to the monitor bus and you can listen to the signal via headphones or loudspeaker, either which is connected to the monitor output. Automatic pilot tone surveillance of the two output channels is also integrated. The jumpers for adjusting the output voltage to 0 dB or +6 dB are located on the printed board assembly. At the same time you have to alter the jumper setting of the monitor signal correspondingly.
The output module employs integrated output relays that prevent switching noise from being heard. When switching the system on, the output signal is put through after the system is been initialized
DPM - OUT
A
LINE
OUT 0/+6 dBu
B
LINE
O UT 0/+6 dBu
90218
figure 5.27
Specifications:
description | ||
connections | 2 x |
|
audio |
|
|
outputs | 2, electronically balanced, transformers are optionally available | |
nominal output level | 0 dBu / 775 mV or +6 dBu / 1.55 V, switched via jumper | |
output impedance | 115 |
|
frequency response | 20 Hz ... 20 kHz, 0.5 dB |
|
dynamic range | > 97 dB |
|
S/N ratio | > 109 dB |
|
distortion | 0.005 % |
|
| ||
power consumption | 1.5 W |
|
operational temperature range | +5 C ... +40 C |
|
dimensions W x H x D | 37.5 x 81 x 247 mm |
|
weight | 160 g (255 g including 2 x NRS 90227) |
|
extensions | NRS 90227 output transformer for 1 output |
PROANNOUNCE System User Handbook 1.1 |