Hoshizaki KM-630MRF, KM-630MAF, KM-630MWF service manual

Page 14

2)Defrost Timer

The defrost cycle starts when the Float Switch opens and completes the freeze cycle. But the Defrost Timer does not start counting until the Thermistor senses 48°F at the Evaporator outlet. The period from the end of the freeze cycle up to the point of the Thermistor's sensing varies depending on the ambient and water temperatures.

3)High Temperature Safety - 127 ± 7°F

The temperature of the suction line in the refrigerant circuit is limited by the High Tem- perature Safety.

During the defrost cycle the Evaporator temperature rises. The Thermistor senses 48°F and starts the Defrost Timer. After the Defrost Timer counts down to zero, the normal freeze cycle begins. If the Evaporator temperature continues to rise, the Thermistor will sense the rise in temperature and at 127 ± 7°F the Thermistor operates the High Tem- perature Safety.

This High Temperature Safety shuts down the circuit and the icemaker automatically stops. To reset the safety, turn the power off and back on again.

This High Temperature Safety protects the unit from excessive temperature. The Control Board will Beep every 3 seconds. The white Reset Button on the Control Board must be pressed with power on to reset the Safety.

4)Low Water Safety

If the Pump Motor is operated without water, the mechanical seal can fail. To prevent this type of failure, the Controller Board checks the position of the Float Switch at the end of the initial one minute water fill cycle and at the end of each defrost cycle.

If the Float Switch is in the up position (electrical circuit closed), the Controller Board changes to the ice making cycle. If the Float Switch is in the down position (electrical circuit open), the Controller Board changes to a one minute water fill cycle before starting the ice making cycle. This method allows for a Low Water Safety shut down to protect the Water Pump from mechanical seal failure.

For water-cooled model, if the water is shut off, the unit is protected by the High Pressure Switch.

5)High Voltage Cut-out

The maximum allowable supply voltage of this icemaker is limited by the High Voltage Cut-out.

If miswiring (especially on single phase 3 wire models) causes excessive voltage on the Controller Board, the High Voltage Cut-out shuts down the circuit in 3 seconds and the icemaker automatically stops. When the proper supply voltage is resumed, the icemaker automatically starts running again. The Control Board will signal this problem using 7 Beeps every 3 seconds.

6)LED Lights and Audible Alarm Safeties

The red LED indicates proper control voltage and will remain on unless a control voltage

14

Image 14
Contents KM-630MAF KM-630MWF KM-630MRF Hoshizaki AMERICA, INC Contents Maintenance Specifications KM-630MAFKM-630MWF KM-630MRF Condenser Unit URC-6F Model URC-6F II. General Information Construction KM-630MWF KM-630MRF SOLID-STATE Control Features of Control Products E Controller BoardController Board Controller BoardPage Harvest Cycle Beep every 3 sec. = High Evaporator Temperature 127 FMinute Fill Cycle Freeze CycleControl Products HOS-001A Board Sequence 1st Cycle Important Water Valve opening is limited to 6 minutes2nd Cycle and after with pump drain 2nd Cycle and after with no pump drain Controls and Adjustments OFF KM-630MRFSetting Time Setting Frequency Checking the Controller Board Page III. Technical Information KM-630MWF KM-630MRF Wiring Diagrams KM-630MAF and KM-630MWFU1GMA0179608 Timing Chart From Defrost Cycle To Defrost CycleTo Freeze Cycle From Freeze Cycle Performance Data KM-630MWF KM-630MRF IV. Service Diagnosis No ICE Production Problem Possible Cause RemedyController Board Problem Possible Cause Remedy Evaporator is Frozen UP LOW ICE ProductionAbnormal ICE OthersRefrigerant Recovery Removal and Replacement of ComponentsService for Refrigerant Lines Evacuation and Recharge R-404ABrazing Removal and Replacement of Compressor Important Page Removal and Replacement of Drier Removal and Replacement of Expansion ValveRemoval and Replacement of HOT GAS Valve and Line Valve Page Removal and Replacement of Evaporator Important Page Adjustment of Water Regulating Valve WATER-COOLED Model only Page Removal and Replacement of Thermistor Caution Removal and Replacement of FAN Motor Removal and Replacement of Water Valve Removal and Replacement of Pump MotorRemoval and Replacement of Spray Tubes VI. Maintenance and Cleaning Instructions Preparing the Icemaker for Long StoragePage Cleaning Cleaning Procedure Page Sanitizing Procedure Following Cleaning Procedure Maintenance

KM-630MRF, KM-630MWF, KM-630MAF specifications

The Hoshizaki KM-630MWF, KM-630MAF, and KM-630MRF are advanced commercial ice machines designed to meet the needs of various businesses, including restaurants, bars, and cafes. Renowned for their efficiency, durability, and performance, these models showcase Hoshizaki's dedication to innovation in the foodservice industry.

One of the primary features of the Hoshizaki KM-630 series is the production of crescent-shaped ice. This type of ice is not only aesthetically pleasing but also known for its slow melting properties, making it ideal for keeping beverages cold without diluting them quickly. With a production capacity of up to 617 pounds of ice per day, these machines are built to handle high-demand scenarios efficiently.

The KM-630MWF model is equipped with a water-cooled condenser, making it suitable for environments where air-cooled units might face challenges due to high ambient temperatures. In contrast, the KM-630MAF features an air-cooled condenser which is advantageous for businesses looking to reduce water usage. The KM-630MRF variant utilizes a remote-cooled option, offering flexibility in installation and reducing heat and noise in the kitchen areas.

All three models are built with superior quality stainless steel, ensuring durability and resistance to rust and corrosion. They are designed to be easy to clean, featuring a smooth surface that minimizes dirt and bacteria buildup. Furthermore, Hoshizaki incorporates their advanced EverCheck alert system, providing operators with real-time performance notifications and ensuring reliable operation.

Energy efficiency is a crucial characteristic of the KM-630 series. These machines are designed to comply with industry standards, significantly reducing energy consumption and operating costs. Their highly efficient refrigeration system not only enhances ice production but also extends the lifespan of the machine.

In terms of ease of use, Hoshizaki has designed the KM-630 series to feature a user-friendly control panel. This panel allows for straightforward monitoring and modification of operations, ensuring operators can manage the machine effectively.

Overall, the Hoshizaki KM-630MWF, KM-630MAF, and KM-630MRF ice machines represent a blend of advanced technology, energy efficiency, and robust construction, making them an ideal choice for businesses that demand high-quality ice production. With their innovative features, these machines are poised to elevate the service capabilities of any establishment.