GE Monogram Comprehensive Guide to Ice Maker Cleaning and Maintenance

Page 12

Care and Cleaning

Icemaker

Icemaker system

1.Press and hold the OFF button for 3 seconds.

2.Wait 5 to 10 minutes for the ice to fall into the storage bin. Remove all ice from the storage bin.

3.Unscrew the drain cap from the bottom of the water reservoir located inside the storage bin as shown. Allow the water to drain completely.

seconds. The CLEAN light will begin to blink, indicating that the cleaning cycle is in process. The cleaning time is approximately 70 minutes.

Drain cap

Water reservoir

4.Replace the drain cap.

5.For best results, use the entire 16 oz. bottle of Nickel Safe Ice Machine Cleaner. Follow all safety precautions on the bottle. Pour one bottle of solution into the water reservoir. Fill the bottle twice with tap water and pour it into the water reservoir.

Nickel Safe Ice Machine Cleaner by Nu Calgon is available at appliance repair shops, or through GE Parts and Accessories. Order part number WX08X42870. In the U.S.A., call 800.626.2002 or visit monogram.com. In Canada, call 1.800.561.3344.

6.Press and hold the CLEAN button for 3

7. When the indicator light becomes solid and remains lit, the cleaning cycle is complete. During the cleaning cycle, the system will both clean and rinse itself.

8.After the cleaning cycle is complete, remove the drain cap from the water reservoir to see if any cleaning solution, green in color, is left in the water reservoir. If cleaning solution drains from the water reservoir, you should run the clean cycle again adding only tap water to the reservoir. Be sure to replace the drain cap before running the cycle again. If the cap is not securely tightened, water can leak, causing thin ice or no ice.

NOTE: Severe scale buildup may require repeated cleaning with a fresh quantity of cleaning solution.

9.Press the ON button for 3 seconds to resume ice production.

Condenser

For best performance, brush or vacuum lint and dirt from the condenser at least once a year.

A dirty or clogged condenser:

Use more energy..

Prevents proper airflow.

Reduces ice making capacity.

Causes higher than recommended operating temperatures which may lead to component failure.

1.Unplug the icemaker or disconnect power.

2.Remove the 2 screws in the lower access panel and the 2 screws from the base grille area of the front panel support. Pull forward to remove the lower access panel.

3.Pull the bottom forward and then pull down to remove the lower access panel.

4.Remove dirt and lint from the condenser fins and the unit compartment with a brush attachment attached to a vacuum cleaner.

5.Replace the lower access panel using the 4 screws.

6.Plug in the icemaker or reconnect power.

12

Image 12
Contents ZDIC150 ZDIS150 Monogram.comContents Before using your icemakerWrite down the model & serial numbers If you need service For customers in the USARead and Save These Instructions It is your responsibility to be sure your icemakerLire ET Conserver CES Instructions Avertissement PourRaccordement Électrique Extension CordsRallonges Refrigerants RéfrigérantsRemove packaging Set controlsFeatures of your icemaker How your icemaker works Making IceCaring for your icemaker Exterior surfacesDo not use appliance wax or polish on the stainless steel Icemaker system CondenserDirty or clogged condenser Vacation and moving To shut down the icemakerQuestions? Use this problem solver Problem Solver Problem Possible CauseConsumer Services From the Date Original Purchase GE Consumer & Industrial

ZDIC150, ZDIS150 specifications

The GE Monogram ZDIS150 and ZDIC150 are premium built-in ice makers designed to cater to the needs of discerning homeowners and culinary enthusiasts. These modern appliances seamlessly blend functionality with elegance, making them a vital addition to any upscale kitchen or bar area.

One of the standout features of the ZDIS150 and ZDIC150 is their ability to produce an impressive amount of clear, gourmet ice. The ZDIS150 can produce up to 65 pounds of ice in a day, while the ZDIC150 offers a similar output, ensuring that you have a steady supply for entertaining guests or family gatherings. The clear ice generated by these units not only looks visually appealing but also melts slower than traditional ice, ensuring your drinks maintain their chill without dilution.

In terms of technology, both models utilize a state-of-the-art, self-dispensing system that simplifies the process of ice retrieval. This system is designed to ensure that accessing ice is as convenient as possible, making them perfect for cocktail parties, barbecues, or everyday use. The appliances are also equipped with an advanced filtration system that enhances the taste and clarity of the ice, utilizing a water filter to eliminate impurities and ensure the highest quality output.

The ZDIS150 and ZDIC150 showcase a sleek stainless-steel finish that complements any kitchen decor, along with customizable panel options for a cohesive look that integrates perfectly with cabinetry. Both models are designed for easy installation, fitting seamlessly into built-in spaces.

These ice makers also feature intuitive digital controls, which make it easy to monitor and adjust settings as needed. Their energy efficiency is another essential characteristic, as both models are designed to minimize energy consumption while maximizing performance.

Lastly, the durability of the GE Monogram ZDIS150 and ZDIC150 is noteworthy. Crafted with high-quality materials, they are built to withstand the test of time, promising reliable performance for years to come.

In summary, the GE Monogram ZDIS150 and ZDIC150 ice makers are superb examples of engineering excellence, blending style, technology, and efficiency. Whether you're a cocktail connoisseur or simply want the convenience of having high-quality ice on hand, these appliances meet and exceed expectations.