SECTION 1: SPECIFICATION INFORMATION
SPECIFICATIONS of the
PERFORMANCE/CAPABILITIES |
| ELECTRICAL REQUIREMENTS |
|
|
| ||||
OPERATING CAPACITY (RACKS/HOUR) |
| WASH MOTOR HP |
|
| 3/4 |
| |||
| RACKS PER HOUR | 24 | NOTE: Typical Electrical Circuit is based upon (1) 125% of the | ||||||
| DISHES PER HOUR | 600 | |||||||
| full amperage load of the machine and (2) typical | ||||||||
|
|
| |||||||
| GLASSES PER HOUR | 600 | cuit breaker sizes as listed in the NEC 2002 Edition. Local | ||||||
|
|
| codes may require more stringent protection than what is dis- | ||||||
|
|
| played here. Always verify with your electrical service con- | ||||||
OPERATING CYCLE (SECONDS) |
| tractor that your circuit protection is adequate and meets all | |||||||
| applicable national and local codes. These numbers are pro- | ||||||||
| WASH TIME | 56 | |||||||
| vided in this manual simply for reference and may change | ||||||||
| DRAIN TIME | 26 | without notice at any given time. |
|
|
| |||
|
|
|
|
|
|
|
| ||
| RINSE TIME | 35 |
|
|
|
|
| ||
| TOTAL CYCLE TIME | 120 |
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| RINSE |
| TYPICAL | |
TEMPERATURES |
| VOLTS | PH | HZ | HEATER | TOTAL | ELECTRICAL | ||
|
|
| RATINGS | AMPS | CIRCUIT | ||||
| WASH | (48.9°C) 120°F | 115 | 1 | 60 | N/A | 14 A | 20 AMP | |
| WASH | (60°C) 140°F | 208 | 1 | 60 | N/A | 7 A | 15 AMP | |
| 230 | 1 | 60 | N/A | 7 A | 15 AMP | |||
| RINSE | (48.9°C) 120°F |
|
|
|
|
|
|
|
| RINSE | (60°C) 140°F | NOTE: Always refer to the machine data plate for specific | ||||||
|
|
| |||||||
|
|
| electrical and water requirements. The material provided on | ||||||
WATER REQUIREMENTS |
| this page is for reference only and may be subject to change | |||||||
INLET TEMPERATURE (RECOMMENDED) | (60°C) 140°F | without notice. |
|
|
|
|
| ||
|
|
|
|
|
|
| |||
INLET TEMPERATURE (MINIMUM) | (48.9°C) 120°F |
|
|
|
|
|
|
| |
WATER LINE SIZE I.P.S. (MINIMUM) | 1/2” |
|
|
|
|
|
|
| |
DRAIN LINE SIZE I.P.S. (MINIMUM) | 1 3/8” |
|
|
|
|
|
|
| |
FLOW PRESSURE P.S.I. | 20 ±5 |
|
|
|
|
|
|
| |
MINIMUM CHLORINE REQUIRED (PPM) | 50 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Issued: