Jackson 300XS, 300XLT, 300XN technical manual Remove the wire nuts from the wires and separate them

Page 28

SECTION 5: SERVICE PROCEDURES

RINSE SOLENOID VALVE REPAIR PARTS KIT (CONTINUED)

Prying open the coil wire cover

4.When replacing the coil, ensure that when removing the coil wire cover that care is taken not to damage the wires inside. Using the medium flathead screwdriver, gently use it to open the cover enough to where it could be pulled off.

Straightening the wires

5.Once the coil wire cover has been removed and set to the side, take the internal wires and pull them out straight.

Removing the wire nuts

6. Remove the wire nuts from the wires and separate them.

Loosening the conduit nut

7.Using a pair of channel locks, gently loosen the conduit retaining ring for the conduit nut. Once it is loosened, use your fingers to unscrew and remove it.

8.Pull the conduit away and discard the bad coil. Take the new coil and attach the conduit, reinstall & tighten the conduit nut, and pull the wires through so that you will be able to wire the valve back up.

9.Reconnect the wires from the conduit to the wires from the solenoid as they had been connected previously. Ensure that the wire nuts are on tight.

10.Slide the coil wire cover back on, taking care not to dam- age the wires.

11.If you are done performing maintenance on the valve, con- tinue on to step 22. Otherwise, please go on to step 12.

Loosening the valve bonnet

12.To remove the valve bonnet, grasp it with the jaws of the pipe wrench and turn to the left. Note: on some models you may have to remove the valve in order to perform this and any further steps. Be careful not to damage the plumbing assem- bly. Only use the pipe wrench enough to where you can spin the valve bonnet off with your hand.

300X Series Technical Manual 7610-002-64-22

Issued: 07-26-2006 Revised: N/A

23

Image 28
Contents Technical Manual For Jackson ModelsPage Revision Made Applicable Details Date ECN 300XS Nomenclature for the Models Covered in this ManualTable of Contents Section Specification Information Specification Information Electrical Requirements 300X Dimensions 300XN & 300XLT Dimensions Table Dimensions Corner InstallationSection INSTALLATION/OPERATION Instructions INSTALLATION/OPERATION Instructions Installation InstructionsElectrical Connection 300X System Flow Diagram Dishmachine300XN/XLT System Flow Diagram 300XS System Flow Diagram Detergent Control Operation Instructions INSTALLATION/OPERATION Instructions Section Preventative Maintenance Preventative Maintenance Section Troubleshooting Troubleshooting Common ProblemsProblem Doors will not close completely Section Service Procedures Service Procedures PreparationTools Required Time RequiredRemove the wire nuts from the wires and separate them Removing the valve bonnet After Maintenance Actions Special PartsVacuum Breaker Repair Parts KIT Preparation StepsRemoving the plunger Rinse Regulating Thermostat Replacement Location of the thermostat bracket JP-24 Sliding imperial fitting onto new thermostat Special Notes Section Parts Section Control BOX Assembly Parts SectionQTY Description Hood Assembly Cantilever ARM/DOOR Assemblies Cantilever Arm Frame Assembly TUB Assembly Parts Section Steam TUB Assembly See page entitled Wash Motors Gasket Rinse Tank Assembly Thermostats / Wash Heaters / Rinse Heaters Rinse Heater 12 KW Rinse Heater 14 KWWash Pump Exploded View Model Volts Phase Wash Motor Assembly Wash MotorsIncoming Plumbing Water Pressure Regulator KIT Wprk Option Incoming Plumbing Outlet Plumbing 300XN & 300XS Incoming Plumbing Assembly Litem QTY DescriptionRinse Solenoid Valve & Vacuum Breaker Repair Parts Kits 300XS Incoming Steam Plumbing Assemblies Coil Assembly 300XS Detail a Final Rinse Arms & Manifold Wash & Rinse ARM/MANIFOLD AssembliesExploded View Safety Door Interlock SDI Option Exhaust FAN Control Option False Panel Installation False panel positioned in unitDrain Quench Assembly To Cold Water SupplySection Electrical Schematics Electrical Schematics 300X/300XN/300XLT 380-440-460 Volt 50/60 Hertz Three Phase 300X/300XN/300XLT 415 Volt 50/60 Hertz Three Phase Electrical Schematics

300X, 300XN, 300XLT, 300XS specifications

The Jackson 300 series presents a range of advanced air conditioning units that cater to diverse heating and cooling needs. Notable models include the 300X, 300XLT, 300XN, and 300XS, each equipped with distinct features that enhance performance, efficiency, and user comfort.

The Jackson 300X stands out with its cutting-edge inverter technology, which enables precise temperature control while minimizing energy consumption. Its variable-speed compressor adjusts to real-time conditions, ensuring consistent comfort and significant savings on utility bills. The model is also recognized for its robust build quality, designed to withstand extreme weather conditions.

On the other hand, the 300XLT model takes energy efficiency to the next level. This unit incorporates a high-efficiency condenser and evaporator coils, promoting improved heat exchange and reduced energy loss. Additionally, it utilizes eco-friendly refrigerants that comply with environmental regulations, making it a responsible choice for conscious consumers.

The 300XN variant is tailored for noise-sensitive environments, such as bedrooms and offices. This silent operation feature allows the unit to run at remarkably low decibel levels, providing comfort without the disruption of loud HVAC systems. The 300XN also boasts an advanced filtration system that improves indoor air quality, capturing dust and allergens effectively.

Lastly, the Jackson 300XS is designed for exceptional versatility. This model offers multiple installation options, making it suitable for various spaces, from residential to commercial settings. Equipped with smart connectivity features, the 300XS can be controlled remotely via a smartphone app, allowing users to adjust settings on-the-go.

All models come with a user-friendly interface, allowing for easy temperature adjustments and filter change notifications. The durability of these units is further enhanced by their corrosion-resistant materials, extending their lifespan and performance.

In summary, the Jackson 300 series features models like the 300X, 300XLT, 300XN, and 300XS, each offering unique advantages. With a blend of innovative technologies, energy efficiency, and user-friendly controls, these air conditioning units provide tailored solutions to meet varied environmental demands, ensuring optimal comfort year-round. Whether for residential or commercial use, Jackson's offerings underscore a commitment to quality and performance, making them a notable choice in today’s HVAC market.