Jackson 300XLT, 300XS, 300XN technical manual Table of Contents

Page 5

TABLE OF CONTENTS

SECTION

DESCRIPTION

PAGE

I.

SPECIFICATION INFORMATION

 

 

Operating Capacities

2

 

Electrical Requirements

3

 

Dimensions

4

 

300XN/300XLT Dimensions

5

 

Table Dimensions

6

II.

INSTRUCTION/OPERATION INSTRUCTIONS

 

 

Installation Instructions

8

 

300X System Flow Diagram

10

 

300XN/XLT System Flow Diagram

11

 

300XS System Flow Diagram

12

 

Detergent Control

13

 

Operation Instructions

14

III.

PREVENTATIVE MAINTENANCE

17

IV.

TROUBLESHOOTING SECTION

19

V.

SERVICE PROCEDURES

 

 

Rinse Solenoid Valve Repair Parts Kit

22

 

Vacuum Breaker Repair Parts Kit

26

 

Rinse Regulating Thermostat Replacement

28

VI.

PARTS SECTION

 

 

Control Box Assembly

33

 

Hood Assembly

35

 

Cantilever Arm/Door Assemblies

36

 

Frame Assembly

38

 

Tub Assembly

39

 

Steam Tub Assembly

41

 

RinseTank Assembly

43

 

Thermostats/Wash Heaters/Rinse Heaters

44

 

Wash Pump Exploded View

45

 

Wash Motors

46

 

Water Pressure Regulator Kit (WPRK) Option Plumbing

47

 

Incoming Plumbing Assembly

47

 

Outlet Plumbing Assembly

49

 

300XN/300XS Incoming Plumbing Assembly

50

 

Vacuum Breaker Repair Kit (1/2” NPT)

51

 

Solenoid Valve Repair Parts

51

 

300XS Incoming Steam Plumbing Assemblies

52

 

300XS Steam Coil Assembly

53

 

Wash and Rinse Arm/Manifold Assemblies

54

 

Safety Door Interlock (SDI) Option

56

 

Exhaust Fan Control Option

57

 

False Panel Kit Option

58

 

Drain Quench Kit Option

59

VII.

ELECTRICAL DIAGRAMS

 

 

208V - 230V, 50/60 Hz, single/three phase 300X/XN/XLT

61

 

380V - 440V - 460V, 50/60 Hz, three phase 300X/XN/XLT

62

 

415V, 50/60 Hz, three phase 300X/XN/XLT

63

 

208V - 230V - 380V - 460V, 50/60 Hz, single/three phase 300XS

64

 

 

 

 

 

 

i

Image 5
Contents For Jackson Models Technical ManualPage Revision Made Applicable Details Date ECN Nomenclature for the Models Covered in this Manual 300XSTable of Contents Section Specification Information Specification Information Electrical Requirements 300X Dimensions 300XN & 300XLT Dimensions Corner Installation Table DimensionsSection INSTALLATION/OPERATION Instructions Installation Instructions INSTALLATION/OPERATION InstructionsElectrical Connection Dishmachine 300X System Flow Diagram300XN/XLT System Flow Diagram 300XS System Flow Diagram Detergent Control Operation Instructions INSTALLATION/OPERATION Instructions Section Preventative Maintenance Preventative Maintenance Section Troubleshooting Common Problems TroubleshootingProblem Doors will not close completely Section Service Procedures Preparation Service ProceduresTools Required Time RequiredRemove the wire nuts from the wires and separate them Removing the valve bonnet Special Parts After Maintenance ActionsPreparation Steps Vacuum Breaker Repair Parts KITRemoving the plunger Rinse Regulating Thermostat Replacement Location of the thermostat bracket JP-24 Sliding imperial fitting onto new thermostat Special Notes Section Parts Section Parts Section Control BOX AssemblyQTY Description Hood Assembly Cantilever ARM/DOOR Assemblies Cantilever Arm Frame Assembly TUB Assembly Parts Section Steam TUB Assembly See page entitled Wash Motors Gasket Rinse Tank Assembly Rinse Heater 12 KW Rinse Heater 14 KW Thermostats / Wash Heaters / Rinse HeatersWash Pump Exploded View Wash Motors Model Volts Phase Wash Motor AssemblyIncoming Plumbing Water Pressure Regulator KIT Wprk Option Incoming Plumbing Outlet Plumbing Litem QTY Description 300XN & 300XS Incoming Plumbing AssemblyRinse Solenoid Valve & Vacuum Breaker Repair Parts Kits 300XS Incoming Steam Plumbing Assemblies Coil Assembly 300XS Wash & Rinse ARM/MANIFOLD Assemblies Detail a Final Rinse Arms & ManifoldExploded View Safety Door Interlock SDI Option Exhaust FAN Control Option False panel positioned in unit False Panel InstallationTo Cold Water Supply Drain Quench AssemblySection Electrical Schematics Electrical Schematics 300X/300XN/300XLT 380-440-460 Volt 50/60 Hertz Three Phase 300X/300XN/300XLT 415 Volt 50/60 Hertz Three Phase Electrical Schematics

300X, 300XN, 300XLT, 300XS specifications

The Jackson 300 series presents a range of advanced air conditioning units that cater to diverse heating and cooling needs. Notable models include the 300X, 300XLT, 300XN, and 300XS, each equipped with distinct features that enhance performance, efficiency, and user comfort.

The Jackson 300X stands out with its cutting-edge inverter technology, which enables precise temperature control while minimizing energy consumption. Its variable-speed compressor adjusts to real-time conditions, ensuring consistent comfort and significant savings on utility bills. The model is also recognized for its robust build quality, designed to withstand extreme weather conditions.

On the other hand, the 300XLT model takes energy efficiency to the next level. This unit incorporates a high-efficiency condenser and evaporator coils, promoting improved heat exchange and reduced energy loss. Additionally, it utilizes eco-friendly refrigerants that comply with environmental regulations, making it a responsible choice for conscious consumers.

The 300XN variant is tailored for noise-sensitive environments, such as bedrooms and offices. This silent operation feature allows the unit to run at remarkably low decibel levels, providing comfort without the disruption of loud HVAC systems. The 300XN also boasts an advanced filtration system that improves indoor air quality, capturing dust and allergens effectively.

Lastly, the Jackson 300XS is designed for exceptional versatility. This model offers multiple installation options, making it suitable for various spaces, from residential to commercial settings. Equipped with smart connectivity features, the 300XS can be controlled remotely via a smartphone app, allowing users to adjust settings on-the-go.

All models come with a user-friendly interface, allowing for easy temperature adjustments and filter change notifications. The durability of these units is further enhanced by their corrosion-resistant materials, extending their lifespan and performance.

In summary, the Jackson 300 series features models like the 300X, 300XLT, 300XN, and 300XS, each offering unique advantages. With a blend of innovative technologies, energy efficiency, and user-friendly controls, these air conditioning units provide tailored solutions to meet varied environmental demands, ensuring optimal comfort year-round. Whether for residential or commercial use, Jackson's offerings underscore a commitment to quality and performance, making them a notable choice in today’s HVAC market.