Jackson 300XS, 300XLT, 300XN False panel positioned in unit, False Panel Installation

Page 63

FALSE PANEL INSTALLATION

Left & Front False Panel

Weldment 05700-002-75-52

Right False Panel Weldment (Use with Overflow Tube Lifter)

05700-002-98-85

Left & Front False Panel Kit

05700-002-75-59

Right False Panel Kit

(Use with Overflow Tube Lifter)

05700-002-98-96

SECTION 6: PARTS SECTION

Rack rail removed & reposi- tioned for a corner operation.

Insert this side first.

False panel positioned in unit.

1.Loosen the rack assembly from the unit.

2.False panel will mount to the rack; inside the dishmachine.

3. Position panel in unit on side to be closed.

4.Hold panel against side of dishmachine and push up.

5.Panel will clip inside the unit under the edge of the hood.

6.Holes in false panel willl ine up with rack assembly holes.

7.Re-install screws for rack assembly which will secure false panel to unit.

8.Re-assemble the rack track in an “L” shape for a corner opera- tion.

Bottom of side panel.

300X Series Technical Manual 7610-002-64-22

Issued: 07-26-2006 Revised: N/A

58

Image 63
Contents For Jackson Models Technical ManualPage Revision Made Applicable Details Date ECN Nomenclature for the Models Covered in this Manual 300XSTable of Contents Section Specification Information Specification Information Electrical Requirements 300X Dimensions 300XN & 300XLT Dimensions Corner Installation Table DimensionsSection INSTALLATION/OPERATION Instructions Installation Instructions INSTALLATION/OPERATION InstructionsElectrical Connection Dishmachine 300X System Flow Diagram300XN/XLT System Flow Diagram 300XS System Flow Diagram Detergent Control Operation Instructions INSTALLATION/OPERATION Instructions Section Preventative Maintenance Preventative Maintenance Section Troubleshooting Common Problems TroubleshootingProblem Doors will not close completely Section Service Procedures Time Required Service ProceduresPreparation Tools RequiredRemove the wire nuts from the wires and separate them Removing the valve bonnet Special Parts After Maintenance ActionsPreparation Steps Vacuum Breaker Repair Parts KITRemoving the plunger Rinse Regulating Thermostat Replacement Location of the thermostat bracket JP-24 Sliding imperial fitting onto new thermostat Special Notes Section Parts Section Parts Section Control BOX AssemblyQTY Description Hood Assembly Cantilever ARM/DOOR Assemblies Cantilever Arm Frame Assembly TUB Assembly Parts Section Steam TUB Assembly See page entitled Wash Motors Gasket Rinse Tank Assembly Rinse Heater 12 KW Rinse Heater 14 KW Thermostats / Wash Heaters / Rinse HeatersWash Pump Exploded View Wash Motors Model Volts Phase Wash Motor AssemblyIncoming Plumbing Water Pressure Regulator KIT Wprk Option Incoming Plumbing Outlet Plumbing Litem QTY Description 300XN & 300XS Incoming Plumbing AssemblyRinse Solenoid Valve & Vacuum Breaker Repair Parts Kits 300XS Incoming Steam Plumbing Assemblies Coil Assembly 300XS Wash & Rinse ARM/MANIFOLD Assemblies Detail a Final Rinse Arms & ManifoldExploded View Safety Door Interlock SDI Option Exhaust FAN Control Option False panel positioned in unit False Panel InstallationTo Cold Water Supply Drain Quench AssemblySection Electrical Schematics Electrical Schematics 300X/300XN/300XLT 380-440-460 Volt 50/60 Hertz Three Phase 300X/300XN/300XLT 415 Volt 50/60 Hertz Three Phase Electrical Schematics

300X, 300XN, 300XLT, 300XS specifications

The Jackson 300 series presents a range of advanced air conditioning units that cater to diverse heating and cooling needs. Notable models include the 300X, 300XLT, 300XN, and 300XS, each equipped with distinct features that enhance performance, efficiency, and user comfort.

The Jackson 300X stands out with its cutting-edge inverter technology, which enables precise temperature control while minimizing energy consumption. Its variable-speed compressor adjusts to real-time conditions, ensuring consistent comfort and significant savings on utility bills. The model is also recognized for its robust build quality, designed to withstand extreme weather conditions.

On the other hand, the 300XLT model takes energy efficiency to the next level. This unit incorporates a high-efficiency condenser and evaporator coils, promoting improved heat exchange and reduced energy loss. Additionally, it utilizes eco-friendly refrigerants that comply with environmental regulations, making it a responsible choice for conscious consumers.

The 300XN variant is tailored for noise-sensitive environments, such as bedrooms and offices. This silent operation feature allows the unit to run at remarkably low decibel levels, providing comfort without the disruption of loud HVAC systems. The 300XN also boasts an advanced filtration system that improves indoor air quality, capturing dust and allergens effectively.

Lastly, the Jackson 300XS is designed for exceptional versatility. This model offers multiple installation options, making it suitable for various spaces, from residential to commercial settings. Equipped with smart connectivity features, the 300XS can be controlled remotely via a smartphone app, allowing users to adjust settings on-the-go.

All models come with a user-friendly interface, allowing for easy temperature adjustments and filter change notifications. The durability of these units is further enhanced by their corrosion-resistant materials, extending their lifespan and performance.

In summary, the Jackson 300 series features models like the 300X, 300XLT, 300XN, and 300XS, each offering unique advantages. With a blend of innovative technologies, energy efficiency, and user-friendly controls, these air conditioning units provide tailored solutions to meet varied environmental demands, ensuring optimal comfort year-round. Whether for residential or commercial use, Jackson's offerings underscore a commitment to quality and performance, making them a notable choice in today’s HVAC market.