Jackson 300XS, 300XLT, 300XN technical manual Wash Motors, Model Volts Phase Wash Motor Assembly

Page 51

SECTION 6: PARTS SECTION

WASH MOTORS

The 300X models covered in this manual come supplied with various wash motor assemblies (a wash motor assembly includes the wash motor and the pump end), depending on the characteristics of the machine. To ensure that you order the correct wash motor assembly for the model you are servicing, please refer to the following table:

Model

Volts

Hz

Phase

Wash Motor Assembly

Important note: When servicing a wash

 

 

 

 

 

motor, it is important to refer to the wiring

300X

208

50

1

06105-002-19-87

schematic found on the motor, to ensure that

300X

208

50

3

06105-002-19-87

the motor is wired correctly. Different manu-

300X

208

60

1

06105-121-35-18

facturers of motors may not use the same

300X

208

60

3

06105-121-35-18

wire color codes and therefore, your new

300X

230

50

1

06105-002-19-87

motor, which may have been built by some-

300X

230

50

3

06105-002-19-87

one different than who built your original

300X

230

60

1

06105-121-35-18

motor, may not connect using the same wires.

300X

230

60

3

06105-121-35-18

Always refer to the wiring diagrams on the

300X

380

50

3

06105-002-41-24

motor you are installing. If the motor you are

300X

415

50

3

06105-002-41-24

installing has had the schematic removed,

300X

440

50

3

06105-002-41-24

contact Jackson MSC immediately for techni-

300X

460

60

3

06105-121-64-21

cal support.

300XN

208

50

1

06105-002-19-87

 

 

300XN

208

50

3

06105-002-19-87

 

300XN

208

60

1

06105-121-35-18

 

300XN

208

60

3

06105-121-35-18

 

300XN

230

50

1

06105-002-19-87

 

300XN

230

50

3

06105-002-19-87

 

300XN

230

60

1

06105-121-35-18

 

300XN

230

60

3

06105-121-35-18

 

300XN

380

50

3

06105-002-41-24

 

300XN

415

50

3

06105-002-41-24

 

300XN

440

50

3

06105-002-41-24

 

300XN

460

60

3

06105-121-64-21

 

300XLT

208

50

1

06105-002-19-87

 

300XLT

208

50

3

06105-002-19-87

 

300XLT

208

60

1

06105-121-35-18

 

300XLT

208

60

3

06105-121-35-18

 

300XLT

230

50

1

06105-002-19-87

 

300XLT

230

50

3

06105-002-19-87

 

300XLT

230

60

1

06105-121-35-18

 

300XLT

230

60

3

06105-121-35-18

 

300XLT

380

50

3

06105-002-41-24

 

300XLT

415

50

3

06105-002-41-24

 

300XLT

440

50

3

06105-002-41-24

 

300XLT

460

60

3

06105-121-64-21

 

300XS

208

60

1

06105-121-35-18

 

300XS

230

60

1

06105-121-35-18

 

300XS

208

60

3

06105-121-35-18

 

300XS

230

60

3

06105-121-35-18

 

300XS

380

50

3

06105-002-41-24

 

300XS

460

60

3

06105-121-64-21

 

300X Series Technical Manual 7610-002-64-22

Issued: 07-26-2006 Revised: N/A

46

Image 51
Contents For Jackson Models Technical ManualPage Revision Made Applicable Details Date ECN Nomenclature for the Models Covered in this Manual 300XSTable of Contents Section Specification Information Specification Information Electrical Requirements 300X Dimensions 300XN & 300XLT Dimensions Corner Installation Table DimensionsSection INSTALLATION/OPERATION Instructions Installation Instructions INSTALLATION/OPERATION InstructionsElectrical Connection Dishmachine 300X System Flow Diagram300XN/XLT System Flow Diagram 300XS System Flow Diagram Detergent Control Operation Instructions INSTALLATION/OPERATION Instructions Section Preventative Maintenance Preventative Maintenance Section Troubleshooting Common Problems TroubleshootingProblem Doors will not close completely Section Service Procedures Time Required Service ProceduresPreparation Tools RequiredRemove the wire nuts from the wires and separate them Removing the valve bonnet Special Parts After Maintenance ActionsPreparation Steps Vacuum Breaker Repair Parts KITRemoving the plunger Rinse Regulating Thermostat Replacement Location of the thermostat bracket JP-24 Sliding imperial fitting onto new thermostat Special Notes Section Parts Section Parts Section Control BOX AssemblyQTY Description Hood Assembly Cantilever ARM/DOOR Assemblies Cantilever Arm Frame Assembly TUB Assembly Parts Section Steam TUB Assembly See page entitled Wash Motors Gasket Rinse Tank Assembly Rinse Heater 12 KW Rinse Heater 14 KW Thermostats / Wash Heaters / Rinse HeatersWash Pump Exploded View Wash Motors Model Volts Phase Wash Motor AssemblyIncoming Plumbing Water Pressure Regulator KIT Wprk Option Incoming Plumbing Outlet Plumbing Litem QTY Description 300XN & 300XS Incoming Plumbing AssemblyRinse Solenoid Valve & Vacuum Breaker Repair Parts Kits 300XS Incoming Steam Plumbing Assemblies Coil Assembly 300XS Wash & Rinse ARM/MANIFOLD Assemblies Detail a Final Rinse Arms & ManifoldExploded View Safety Door Interlock SDI Option Exhaust FAN Control Option False panel positioned in unit False Panel InstallationTo Cold Water Supply Drain Quench AssemblySection Electrical Schematics Electrical Schematics 300X/300XN/300XLT 380-440-460 Volt 50/60 Hertz Three Phase 300X/300XN/300XLT 415 Volt 50/60 Hertz Three Phase Electrical Schematics

300X, 300XN, 300XLT, 300XS specifications

The Jackson 300 series presents a range of advanced air conditioning units that cater to diverse heating and cooling needs. Notable models include the 300X, 300XLT, 300XN, and 300XS, each equipped with distinct features that enhance performance, efficiency, and user comfort.

The Jackson 300X stands out with its cutting-edge inverter technology, which enables precise temperature control while minimizing energy consumption. Its variable-speed compressor adjusts to real-time conditions, ensuring consistent comfort and significant savings on utility bills. The model is also recognized for its robust build quality, designed to withstand extreme weather conditions.

On the other hand, the 300XLT model takes energy efficiency to the next level. This unit incorporates a high-efficiency condenser and evaporator coils, promoting improved heat exchange and reduced energy loss. Additionally, it utilizes eco-friendly refrigerants that comply with environmental regulations, making it a responsible choice for conscious consumers.

The 300XN variant is tailored for noise-sensitive environments, such as bedrooms and offices. This silent operation feature allows the unit to run at remarkably low decibel levels, providing comfort without the disruption of loud HVAC systems. The 300XN also boasts an advanced filtration system that improves indoor air quality, capturing dust and allergens effectively.

Lastly, the Jackson 300XS is designed for exceptional versatility. This model offers multiple installation options, making it suitable for various spaces, from residential to commercial settings. Equipped with smart connectivity features, the 300XS can be controlled remotely via a smartphone app, allowing users to adjust settings on-the-go.

All models come with a user-friendly interface, allowing for easy temperature adjustments and filter change notifications. The durability of these units is further enhanced by their corrosion-resistant materials, extending their lifespan and performance.

In summary, the Jackson 300 series features models like the 300X, 300XLT, 300XN, and 300XS, each offering unique advantages. With a blend of innovative technologies, energy efficiency, and user-friendly controls, these air conditioning units provide tailored solutions to meet varied environmental demands, ensuring optimal comfort year-round. Whether for residential or commercial use, Jackson's offerings underscore a commitment to quality and performance, making them a notable choice in today’s HVAC market.