Keating Of Chicago 2006 warranty Electrical Connection, GAS Leak Testing

Page 6

INSTALLATION

The installer is responsible for attaching the tipping restraint.

ELECTRICAL CONNECTION

The Keating IFM, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, the National Electrical Code, ANSI/NFPA No. 70. or the Canadian Electrical Code, CSAC-22.2 as applicable. A wiring diagram is located on the last page. In the U.S.A. and Canada, the electrical supply must be 120 VAC, 60 Hz.

The Keating Incredible Frying Machine (IFM) is equipped with a 9' neoprene covered, 3 wire electrical cord with a three-pronged grounded plug for protection against electrical shock. This plug must be placed into a 120V properly grounded three-pronged polarized outlet. For proper grounding procedures see local codes, or in the absence of local codes, the National Electrical Code ANSI/NFPA 70 (latest edition) or Canadian Electrical Code CAN 22.2 (latest edition) as applicable.

Before plugging in the fryer, confirm the outlet is properly polarized and grounded. If the hot and neutral terminals are reversed or the outlet is not properly grounded, the burners may not ignite (burner on light will go out after 2-1/2 seconds and the ignition processes will continue 3 times).

THIS APPLIANCE IS EQUIPPED

WITH A THREE-PRONG 120

VOLT NEMA 5-15 (GROUNDING)

PLUG FOR YOUR PROTECTION

AGAINST SHOCK HAZARD AND

SHOULD BE PLUGGED

DIRECTLY INTO A PROPERLY

GROUNDED AND POLARIZED

THREE-PRONG RECEPTACLE.

DO NOT CUT OR REMOVE THE

GROUNDING PRONG FROM

THIS PLUG.

IF DISCONNECTION OF THE RESTRAINT IS NECESSARY, IT MUST BE RECONNECTED WHEN THE FRYER IS RETURNED TO ITS ORIGINALLY INSTALLED POSITION.

GAS CONNECTION

PIPE JOINT COMPOUNDS RESISTANT TO PROPANE GASES MUST BE USED.

BEFORE OPERATING THIS FRYER, CHECK PIPE JOINTS FOR LEAKS BY USING A SOAP AND WATER SOLUTION ONLY. DO NOT USE AN OPEN FLAME!

Figure 2-3

Main Gas Connection

Connect the fryer to the main gas supply line at the rear of the fryer. The piping should be a minimum of 3/4" NPT supply pipe for a single fryer at the burner mani- fold. Batteries require larger supply lines. Installation must conform to the current local codes and National Fuel Gas Code (U.S.) ANSI Z223. 1/NFPA 54 (latest edition), Natural Gas Installation Code CAN/CGA-B149.1 or Propane Installation Code CAN/CGA-B149.2 (latest edition).

NOTE: If more than one gas fryer is on the same supply line, you may require a larger line. Consult your local gas company to assure adequate volume and pressure. Refer to serial plate for proper gas requirements for your particular model.

NOTE: Piping for a battery should be at least 1 1/4” to 1 1/2” IPS, depending on total BTU input. Consult your local gas supplier for appropriate battery piping size.

NOTE: The electrical wiring diagram for the fryer is located on the inside of the fryer door or in the back of this manual.

GAS LEAK TESTING

Prior to lighting your fryer:

1.Make sure all thermostats, switches and safety valves are in the “OFF” position.

2.Turn main On/Off manual gas valve to the “ON” position.

3.Have your plumber or gas company check for leaks with a soap solution. (NEVER check with an open flame!)

4

Image 6
Contents Contents Series 2006 Fryer ManualRead and Save this Manual for Future Reference Post this Label in a Prominent Location on Your Unit Introduction Clearances Damage During Shipment InstallationInstallation LevelingGAS Leak Testing Electrical ConnectionMaximum Incoming GAS Pressure OperatingGAS Pressure AT Manifold See FigureDigital Timer Resetting to Minutes Seconds Step CookingShut Down Canceling a Cycle Digital Timer ProgrammingPause Feature Cleaning and BOIL-OUTClose drain valve Preventive Maintenance MaintenanceWarranty Repairs Qualified Service PERGas Pressure ServiceService Diagnosis Air FlowCommon Problems Probable Cause Solutions Follow Sequentially SELF-HELP GuideTroubleshooting Chart Problem Probable Cause SolutionBreaker tripped Problem Probable Cause Solution Parts List Drain Valve Pull Rod AssemblyOrdering Parts Corresponds with parts list on Incredible Frying Machine GAS Fryer Rear Drain Model030862 Blower 053726 See pages 23-25 for Control Panel Parts List Incredible Frying Machine GAS Fryer Front Drain ModelThermostat Burner Assembly see Insulation High LimitDescription QTY Part Number IFM Control Panel Parts List with Timers Model IFM Control Panel Parts List Model 2006 CPU Located on Rear Drain Units only Description QTY Part Number 166 16 Burner Replacement KIT Description QTY Wiring Diagrams IFM 120V Connection Diagram no TIMERS, Front Drain Model Control Panel Insert Control Panel Back IFM Model 2006 Front Drain Without Lighted Rocker Switch IFM Model 2006 with Safe and Easy Filter IFM Model 2006 CPU Basket Lift Front Drain Page Page Page Page Effective 5/2006 Effective 5/2006 Warranty Service Information Keating Limited Warranty Card

2006 specifications

Keating of Chicago 2006 is a significant entry in the world of high-performance sports cars, designed to offer an exhilarating driving experience while emphasizing speed, technology, and innovative engineering. Developed by Keating Sports Cars, a British automotive manufacturer known for its dedication to performance and craftsmanship, the 2006 model showcases the brand’s ethos of creating lightweight and powerful vehicles.

One of the standout features of the Keating of Chicago is its striking design, which blends aerodynamic efficiency with aesthetic appeal. The car boasts a low profile and sleek lines that not only catch the eye but also facilitate optimal airflow, reducing drag during high-speed maneuvers. Available in various striking colors, the exterior encapsulates the essence of a true sports car, conveying both aggression and elegance.

At the heart of the Keating of Chicago lies a formidable powertrain. The car is typically equipped with an advanced V8 engine, which can produce over 500 horsepower, ensuring thrilling acceleration and top speeds. This engine is paired with an efficient transmission system, providing seamless gear shifts and enhancing driving pleasure. The lightweight chassis contributes to the car’s impressive power-to-weight ratio, allowing it to leap from 0 to 60 mph in just a few seconds.

In terms of technology, the Keating of Chicago is well-equipped with modern conveniences and enhancements aimed at improving both performance and driver experience. Features such as advanced suspension systems, performance brakes, and traction control systems ensure that drivers experience unparalleled handling and stability on various terrains. The integration of digital dashboards provides essential information at a glance, allowing drivers to monitor vital metrics while maintaining focus on the road ahead.

The interior of the Keating of Chicago is designed with driver comfort in mind, offering a minimalist yet functional layout that prioritizes ergonomics and user experience. High-quality materials and bespoke options allow for customization, ensuring that each car is as unique as its owner. With comfortable seating and an intuitive control system, the driving experience is both engaging and enjoyable.

Overall, Keating of Chicago 2006 serves as a testament to the manufacturer's commitment to performance, technology, and style. With its potent engine, aerodynamic design, and cutting-edge features, it continues to be a desirable choice for enthusiast drivers seeking a unique blend of performance and luxury in the world of sports cars.