Keating Of Chicago 2006 Warranty Repairs, Preventive Maintenance, Qualified Service PER

Page 11

MAINTENANCE

WARRANTY REPAIRS

Keating’s warranty begins with the date of installation (or ship date if we are not notified of an installation date).

In the event that your fryer, under warranty, needs repairs other than routine maintenance or cleaning, you are required to contact Keating of Chicago (at 1-800-KEATING) before calling a local service company. Failure to do so may void your warranty.

PREVENTIVE MAINTENANCE

Preventive maintenance should be done in daily, week- ly, monthly and yearly intervals as necessary. Following preventive maintenance procedures will help keep your fryer working efficiently. Proper care and servicing will lead to years of quality performance.

A. Oil Breakdown

As part of a “Preventive Maintenance Program”, the oil in your fryer needs to be filtered regularly to avoid breakdown. The initial investment in the frying system is less than the total overall costs of oil during the life of the fryer, and with regular filtering, you can realize sub- stantial savings in oil costs, as well as maintenance charges.

PREVENTIVE MAINTENANCE CHART

TIME

OPERATOR/OWNER

SECTION

FRAME

 

 

Check lights and controls

Check that the oil is up to

Daily*

“Max” line.

III

Clean all baskets

Drain, strain or filter shortening.

Weekly*

• Drain and clean fryer

III & VI

 

Boil-out fryer

 

 

 

 

Monthly*

• Verify thermostat settings.

III

 

• Test Hi-Limit control.

IV & V

 

 

 

 

QUALIFIED SERVICE PER-

 

Yearly*

SONNEL ONLY

V

 

• Check burner flame color and

 

 

adjust air shutters.

 

* High production facilities should be checked more often.

B. Thermostat Calibration

You will need:

One screwdriver with 1/8" wide flat blade

One accurate fryer thermometer

1.Set thermostat to desired frying temperature.

2.Allow fryer to cycle three times.

3.Place an accurate thermometer in the oil at the tip of the thermostat bulb.

Figure 4-1

Dial Plate with knob removed

NOTE: Locate thermometer in same position for every calibration.

4.If calibration of fryer is found to be less than 25°F off, simply loosen the four retaining screws holding the dial plate in place. Reset the dial plate to match the thermometer reading. If the fryer is found to be more than 25°F off, a qualified service company must be contacted to have the fryer properly calibrated.

Do NOT adjust set screw on thermostat.

C. Thermostat Bulb Positioning

BEFORE REPLACING, TEST THERMOSTATS:

Operational problems can easily be corrected by thermostat bulb positioning.

Keating’s patented thermostat application is accurate within 2°F of the dial setting between 250°F – 350°F. This accuracy is attained only if the thermostat bulb is placed properly against the heat transfer tube. To quickly and accurately test for proper bulb placement, a single thickness of writing paper should be pulled through between the tube and the bulb with medium resistance.*

1. *For gas fryers 14":

The end of thermostat bulb should touch the burn- er tube.

2. For gas fryers 18" & up:

If the bulb is too loose, the paper will slip through with little or no resistance. A fryer with a thermo- stat bulb that is too loose will overshoot.

Overshoot: The thermostat takes a long time to cycle and then misses its preset temperature by 20°F - 40°F yielding a poor quality product.

If the bulb is too tight, the paper will either not pull through or it will tear. A fryer with a thermostat bulb that is too tight will short cycle.

9

Image 11
Contents Read and Save this Manual for Future Reference ContentsSeries 2006 Fryer Manual Post this Label in a Prominent Location on Your Unit Introduction Clearances Leveling InstallationInstallation Damage During ShipmentElectrical Connection GAS Leak TestingSee Figure OperatingGAS Pressure AT Manifold Maximum Incoming GAS PressureShut Down Digital Timer Resetting to Minutes Seconds StepCooking Cleaning and BOIL-OUT Digital Timer ProgrammingPause Feature Canceling a CycleClose drain valve Qualified Service PER MaintenanceWarranty Repairs Preventive MaintenanceAir Flow ServiceService Diagnosis Gas PressureSELF-HELP Guide Common Problems Probable Cause Solutions Follow SequentiallyProblem Probable Cause Solution Troubleshooting ChartBreaker tripped Problem Probable Cause Solution Ordering Parts Parts ListDrain Valve Pull Rod Assembly Incredible Frying Machine GAS Fryer Rear Drain Model Corresponds with parts list on030862 Blower 053726 Incredible Frying Machine GAS Fryer Front Drain Model See pages 23-25 for Control Panel Parts ListInsulation High Limit Thermostat Burner Assembly seeDescription QTY Part Number IFM Control Panel Parts List with Timers Model IFM Control Panel Parts List Model 2006 CPU Located on Rear Drain Units only Description QTY Part Number 166 16 Burner Replacement KIT Description QTY Wiring Diagrams IFM 120V Connection Diagram no TIMERS, Front Drain Model Control Panel Insert Control Panel Back IFM Model 2006 Front Drain Without Lighted Rocker Switch IFM Model 2006 with Safe and Easy Filter IFM Model 2006 CPU Basket Lift Front Drain Page Page Page Page Effective 5/2006 Effective 5/2006 Warranty Keating Limited Warranty Card Service Information

2006 specifications

Keating of Chicago 2006 is a significant entry in the world of high-performance sports cars, designed to offer an exhilarating driving experience while emphasizing speed, technology, and innovative engineering. Developed by Keating Sports Cars, a British automotive manufacturer known for its dedication to performance and craftsmanship, the 2006 model showcases the brand’s ethos of creating lightweight and powerful vehicles.

One of the standout features of the Keating of Chicago is its striking design, which blends aerodynamic efficiency with aesthetic appeal. The car boasts a low profile and sleek lines that not only catch the eye but also facilitate optimal airflow, reducing drag during high-speed maneuvers. Available in various striking colors, the exterior encapsulates the essence of a true sports car, conveying both aggression and elegance.

At the heart of the Keating of Chicago lies a formidable powertrain. The car is typically equipped with an advanced V8 engine, which can produce over 500 horsepower, ensuring thrilling acceleration and top speeds. This engine is paired with an efficient transmission system, providing seamless gear shifts and enhancing driving pleasure. The lightweight chassis contributes to the car’s impressive power-to-weight ratio, allowing it to leap from 0 to 60 mph in just a few seconds.

In terms of technology, the Keating of Chicago is well-equipped with modern conveniences and enhancements aimed at improving both performance and driver experience. Features such as advanced suspension systems, performance brakes, and traction control systems ensure that drivers experience unparalleled handling and stability on various terrains. The integration of digital dashboards provides essential information at a glance, allowing drivers to monitor vital metrics while maintaining focus on the road ahead.

The interior of the Keating of Chicago is designed with driver comfort in mind, offering a minimalist yet functional layout that prioritizes ergonomics and user experience. High-quality materials and bespoke options allow for customization, ensuring that each car is as unique as its owner. With comfortable seating and an intuitive control system, the driving experience is both engaging and enjoyable.

Overall, Keating of Chicago 2006 serves as a testament to the manufacturer's commitment to performance, technology, and style. With its potent engine, aerodynamic design, and cutting-edge features, it continues to be a desirable choice for enthusiast drivers seeking a unique blend of performance and luxury in the world of sports cars.