Russound CA-Series instruction manual Rear Panel Connections, Speaker Connections

Page 6

REAR PANEL CONNECTIONS

Figure 3 - CA6.4 Rear Panel Connections

SOURCE INPUT

KEYPAD ZONE INPUT

VOLTAGE SELECTOR

CONNECTIONS

SWITCH

 

CA6.4 NEWMARKET, NH U.S.A.

TUNER

CD

TAPE

 

AUX

R

 

 

 

 

 

L

 

 

 

 

 

12V

IR

 

IR REMOTE OUTPUT

TRIG

LINK

 

 

 

 

100 mA

 

4

3

2

1

 

 

 

PLUG-IN SEQUENCE

 

65

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

6

5

INPUT FROM KEYPADS

4 3

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

OUTPUT TO 8SPEAKERS

4

3

21

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

2

1

DESIGNED BY RUSSOUND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MADE IN KOREA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

~220-240VAC

 

 

~110VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING : SHOCK HAZARD

 

 

 

 

 

 

 

 

 

 

 

 

DO NOT OPEN

 

 

 

 

 

VOLTAGE

FUSE

 

 

 

 

 

110V

F4A

AVIS : RISQUE DE CHOC

 

 

 

 

 

 

 

 

 

 

220-240V

F2A

ELECTRIQUE – NES PAS OUVRIR.

 

 

~110VAC

 

 

 

SERIAL #

 

~220-240VAC

 

 

 

 

 

~50-60Hz

 

 

 

 

 

 

 

 

 

 

 

 

400W

 

 

 

 

 

EMITTER

SPEAKER OUTPUT

AC110/240

FUSE

12V TRIGGER

IR LINK

OUTPUTS

INPUT

HOLDER

OUTPUT

 

CONNECTORS

 

 

Figure 4 - CA4.4pi Rear Panel Connections

SOURCE INPUT

KEYPAD ZONE INPUT

ZONE PREAMP OUTPUTS

VOLTAGE SELECTOR

CONNECTIONS

SWITCH

 

 

 

 

CA4.4 NEWMARKET, NH U.S.A.

 

INPUT FROM KEYPADS

 

 

TUNER

CD

 

TAPE

AUX

4

3

2

1

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

L

 

 

 

 

 

 

OUTPUT TO 8SPEAKERS

 

 

 

 

 

 

 

 

 

12V

IR

IR REMOTE OUTPUT

4

3

2

1

TRIG

LINK

 

 

 

 

 

 

 

 

100mA

 

4

3

2

1

 

 

 

 

 

 

 

USE #1 FIRST

 

 

 

 

 

 

ZONE PREAMP OUTPUTS

 

4

3

2

1

 

TELE-

DOOR

 

PHONE

BELL

 

 

 

MUTE

 

INPUT

~220-240VAC

~110VAC

R

L

WARNING : SHOCK HAZARD

DO NOT OPEN

 

 

 

 

VOLTAGE

FUSE

 

110V

F4A

AVIS : RISQUE DE CHOC

~110VAC

220-240V

F2A

ELECTRIQUE – NES PAS OUVRIR.

~220-240VAC

 

 

 

~50-60Hz

 

 

SERIAL #

400W

 

 

 

EMITTER

SPEAKER OUTPUT

 

AC110/240

FUSE

12V TRIGGER

IR LINK

OUTPUTS

MUTE INPUTS

INPUT

HOLDER

OUTPUT

 

CONNECTORS

 

 

 

SOURCE INPUT CONNECTIONS

 

SPEAKER CONNECTIONS

 

 

Your source inputs are located at the top left corner of the back panel. Although the source input names are silk screened on the back of the CA, these names are for refer- ence only. Any type of source equipment can be connected to any input. Connect each source output, left and right, using quality signal cables / patch cables. Label each cable the name of your source and the input number of the CA you have selected. Repeat until all sources are connected. List them down below.

List 1 – Source names should be written below

Input 1 (TUNER) ____________ Input 2 (CD) ____________

Input 3 (TAPE) ____________ Input 4 (AUX) ____________

Each speaker connection on the back panel corresponds to one room/zone. Wire your speakers by first removing the connector for the chosen zone. Using wire strippers, strip back 1/4" of the end of the wire. Insert the proper polarity, left + to left +, left- to left- etc., until all wires are connect- ed in each zone output. Label each wire with the room name and zone number. Write down the room name to the zone number below. Note: We recommend 8 Ohm minimum speakers for each zone. However, speakers as low as 4 Ohm can be safely used in up to two zones, if necessary.

List 2 – Wire color should be written below

(Color) Left + _______________ Left - _______________

Right + _______________ Right - _______________

List 3 – Room names should be written below

Zone 1 ________________ Zone 2 ________________

Zone 3 ________________ Zone 4 ________________

6

Image 6
Contents CA-Series Important Safeguards Contents Possible System Configurations Product OverviewUnpacking Connection Tips Getting StartedTools Needed FeetRear Panel Connections Speaker ConnectionsList 1 Source names should be written below Zone PRE-AMP Outputs CA4.4PI only IR Remodulator 56K Included AccessoryConnecting the IR Link Volt Trigger OutputWiring Runs UP to 100 Feet Keypad Connections AT ControllerRepeat the above steps until all keypads are installed Installing KeypadsInstalling the Keypads Punchdown TerminalsSetting the Keypads Source Control Keypads OptionSRM-2.1 Speaker Relay Module Option Connect each speaker wire to the correct polarity + Speaker InstallationSpeaker Installation FinallyOperation Operating the Main UnitOperating the CA KP.2 Keypad Lamp PowerOperating the CA-LCD Keypad StoreKeypad Wiring Protection Circuit SpecificationsTroubleshooting Elimination of Balance LineWarranty Combining Additional IR Receivers28-1116 R6