Russound CA-Series Installing Keypads, Punchdown Terminals, Installing the Keypads

Page 9

PUNCHDOWN TERMINALS

Figure 11 – Punchdown Terminal on CA-KP.2 and CA-LCD

2 1 3 6 5 4 8 7

IR

GND

+12V

CH SEL

SEL3

SEL1

BAL

VOL

The CA-KP.2 and CA-LCD come with 110 punchdown termi- nals. These terminals are quick, easy to install and provide a strong connection. Punchdown terminals require the use of a punchdown tool. One has been provided with this kit.

Press wires into punchdown terminal with punchdown tool as shown in Figure 12.

Figure 12 – Punching Down Wires

Punchdown

Tool

IR

IR

GND

+12V

CH SEL

SEL3

SEL1

BAL

VOL

2

1

3

6

5

4

8

7

Connector on

CA-KP.2 or CA-LCD

INSTALLING KEYPADS

INSTALLING THE KEYPADS

The best infrared remote performance is achieved with the keypad away from any direct sunlight. Also consider convenience when choosing a location.

Choose a place that is easily seen from the position where a person is most likely to be located.

Check whether or not you can route the wire to the loca- tion you have chosen.

Purchase retro-fit plastic junction boxes (min. 20 cubic inches) or p-rings and cut in the boxes using a key-hole saw or sheetrock knife/hand saw.

If you are installing the optional DSC keypad you will need to use a double-gang electrical box. If you are installing the CA-LCD, DSC and the optional DAN keypad you will need to install a triple-gang electrical box.

If you feel uncomfortable cutting into your walls and running wire through the walls, seek help from a profes- sional installer or an electrician.

Route the wire to the junction box from the CA location.

If using 22 AWG wire, connect each wire to the correct position 1 thru 8 using the included punchdown tool. Refer to List 5.

If using CAT-5 wire, connect each wire to its correspon- ding color labeled on the punchdown terminal.

Mount the keypad in the junction box and attach the Decora plate.

The CA-KP.2 keypad has source labels for your conven- ience. Insert the label in the keypad keeping the input number in sequence with the source selected.

Repeat the above steps until all keypads are installed.

BROWN

GREEN

ORANGE

BLUE

CAT-5 or 8-conductor

22 AWG wire

9

Image 9
Contents CA-Series Important Safeguards Contents Possible System Configurations Product OverviewUnpacking Tools Needed Getting StartedConnection Tips FeetRear Panel Connections Speaker ConnectionsList 1 Source names should be written below Connecting the IR Link IR Remodulator 56K Included AccessoryZone PRE-AMP Outputs CA4.4PI only Volt Trigger OutputKeypad Connections AT Controller Wiring Runs UP to 100 FeetInstalling the Keypads Installing KeypadsRepeat the above steps until all keypads are installed Punchdown TerminalsSetting the Keypads Source Control Keypads OptionSRM-2.1 Speaker Relay Module Option Speaker Installation Speaker InstallationConnect each speaker wire to the correct polarity + FinallyOperation Operating the Main UnitOperating the CA KP.2 Keypad Operating the CA-LCD Keypad PowerLamp StoreTroubleshooting SpecificationsKeypad Wiring Protection Circuit Elimination of Balance LineCombining Additional IR Receivers Warranty28-1116 R6