Russound CA-Series instruction manual Keypad Connections AT Controller, Wiring Runs UP to 100 Feet

Page 8

KEYPAD CONNECTIONS AT CONTROLLER

Each keypad connection on the back panel of the CA-Series Master Controller corresponds to the room / zone number chosen for your speakers. Each zone operates independently, so it is very important to connect the keypad to the correct zone keypad input.

On List 4 (opposite) copy down the room name to the zone number from List 3 on pg 6. NOTE: the keypad and the speakers in each room must be hooked to the corresponding numbered zone.

Remove the connector and strip 1/8" off each end of the wire insula- tion. Connect each wire 1 thru 8 using a small jewelers screwdriver.

List 4 – Room names should be written below.

Zone 1

_________________

Zone 2

_________________

Zone 3

_________________

Zone 4

_________________

WIRING RUNS UP TO 100 FEET

WIRING RUNS FROM 100-200 FEET

For wiring runs of up to 100 feet in length, we recommend the use of CAT-5 wire. It is inexpensive and color coded for ease of installation. Due to the qualities of CAT-5 wire, when using it for keypad control wire with the CA-Series, it is rec- ommended to use the following color code for maximum performance.

CAT-5

Number

Type

Brown/White

 

1

Ground

Brown

 

2

IR Signal

Green

 

3

12VDC+

Orange/White

 

4

Source Select

Orange

 

5

Source Select

Green/White

 

6

Channel Select

Blue/White

 

7

Volume

Blue

 

8

Balance

Figure 9 – Connections with CAT-5 wire

 

 

INPUT FROM KEYPADS

 

 

4

3

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

 

GREEN

ORANGE BLUE

CAT-5 WIRE

BROWN

 

For wiring runs exceeding 100 feet and extending up to 200 feet, we recommend the use of 8-conductor 22 AWG strand- ed wire such as Russound MCW2418.

If using 22 AWG wire, the order in which you wire is not important as long as you wire in the same order at both the CA unit as well as the keypad. Use List 5 (below) to write down the wire you use for each pin number.

NOTE: Wiring runs longer than 200 feet are not recommend- ed for the CA-Series Keypads.

List 5 –Wire color should be written below.

Pin 1 _______________ Pin 2 _______________

Pin 3 _______________ Pin 4 _______________

Pin 5 _______________ Pin 6 _______________

Pin 7 _______________ Pin 8 _______________

Figure 10 – Connections with 22AWG wire

INPUT FROM KEYPADS

4

3

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

8CONDUCTOR 22AWG STRANDED WIRE

8

Image 8
Contents CA-Series Important Safeguards Contents Unpacking Possible System ConfigurationsProduct Overview Getting Started Tools NeededConnection Tips FeetList 1 Source names should be written below Rear Panel ConnectionsSpeaker Connections IR Remodulator 56K Included Accessory Connecting the IR LinkZone PRE-AMP Outputs CA4.4PI only Volt Trigger OutputWiring Runs UP to 100 Feet Keypad Connections AT ControllerInstalling Keypads Installing the KeypadsRepeat the above steps until all keypads are installed Punchdown TerminalsSRM-2.1 Speaker Relay Module Option Setting the KeypadsSource Control Keypads Option Speaker Installation Speaker InstallationConnect each speaker wire to the correct polarity + FinallyOperating the CA KP.2 Keypad OperationOperating the Main Unit Power Operating the CA-LCD KeypadLamp StoreSpecifications TroubleshootingKeypad Wiring Protection Circuit Elimination of Balance LineWarranty Combining Additional IR Receivers28-1116 R6