10

INSTALLATION

Checking Gas Connections (Cont.) Installing Rod and Screen

INSTALLATION

Continued

Pressure Testing Heater Gas Connections

1.Open equipment shutoff valve (see Figure 9, page 9).

2.Open main gas valve located on or near gas meter for natural gas or open propane.LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to control valve (see Figure 10 or 11). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, page 11). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 11).

INSTALLING ROD AND SCREEN

1.Insert rod through small rings located at top of screen (see Figure 12).

2.From back of stove, insert rod into hole located inside right front of stove as shown in Figure 13.

3.Slip left side of rod down into slot on inside left front of stove (see Figure 13).

Rod

Rings

Control Valve Location

Equipment

Shutoff Valve

Propane/LP

Supply Tank

Figure 12 - Assembling Rod and Screen

 

Slot on Inside Left

Rod with Screen

Hole on Inside Right

Front of Stove

Front of Stove

 

Assembled

 

 

Figure 10 - Checking Gas Joints on Propane/LP Gas Unit

Control Valve Location

Equipment Shutoff Valve

Gas Meter

Figure 13 - Installing Screen Into Stove (View From Back of Stove)

Figure 11 - Checking Gas Joints on Natural Gas Unit

For..com

111487-01C

Page 10
Image 10
Desa CSBNT, CSPIPT, CSPBPT CSPINT, CSBPT CSPBNT Installing ROD and Screen, Pressure Testing Heater Gas Connections