INSTALLATION
Continued
INSTALLING LOG SET
1.Set
2.Fasten back panel to stove with four (4) bolts and washers re- moved in step 4 of Unpacking, page 6. Make sure product iden- tification label is located on the outside lower
3.Place freestanding stove in desired position being careful not to damage gas connections. Be sure to maintain clearances to combustibles and wall clearances as outlined on page 7.
|
| |
|
| Log Set |
|
| Middle Section |
|
| at Bottom of |
|
| Log Set |
|
| Burner |
|
| "U" Shaped |
Heater |
| Cutout in |
FFO | Chassis | |
Base |
|
|
Figure 14 - Installing One-Piece Stove Log Set
Burner Porting Areas (double
Safety Pilot
Location
Figure 15 - Top View of One-Piece Log Set on Gas Log Heater
INSTALLATION | 11 |
Installing Log Set | |
OPERATING HEATER |
|
For Your Safety Read Before Lighting |
|
Lighting Instructions |
|
|
|
OPERATING HEATER
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.
A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance.
•Do not touch any electric switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire de- partment.
C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.
D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING
INSTRUCTIONS
NOTICE: During initial operation of new heater, burning logs will give off a
1.STOP! Read the safety information, abovc.
2.Make sure equipment shutoff valve is fully open.
3. Turn control knob clockwise Clockwise to the OFF position.
4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, above. If you don’t smell gas, go to the next step.
5. Turn control knob counterclockwise
LOT position. Press in control knob for five (5) seconds (see Figure 16, page 12).
For morevisit www..com