Miele DA279-3 installation instructions Functional description, Air extraction, Recirculation mode

Page 10

Functional description

The hood offers two modes of opera- tion:

Air extraction

The air is drawn in and cleaned by the grease filters and directed outside.

The hood comes equipped with a non-return flap. This flap automatically closes when the hood is turned off so that no exchange of outside air and room air can occur. When the hood is turned on, the air pressure of the ex- haust fan automatically opens the flap blowing the inside air and cooking odors outside.

Recirculation mode

Air is drawn through the grease filters and an active charcoal filter. The fil- tered air is then recirculated back into the kitchen through a vent at the top of the hood’s chimney.

Before using the hood in recirculation mode, ensure that the active charcoal filter is in place, see "Cleaning and care".

10

Image 10
Contents Operating and installation instructions Ventilation System Page Table of Contents Important Safety Instructions Use Be Careful to Prevent Burns Installation To reduce the risk of fire, only use metal ductworkGuide to the appliance Grease filter button On/Off button Fan power selectionDelayed shut down Charcoal filter buttonFunctional description Recirculation modeAir extraction Operation Main power switch Selecting the power levelIntensive setting Turning on the fanAutomatic Safety Shut Off Turning off the fanTurning the lighting on/off Indirect lighting Dimming the lightingGrease filters Filter timersChecking the filter timers Charcoal filterReprogramming the timers Reprogramming the grease filter timerReprogramming the charcoal filter timer Stainless steel Cleaning and CareCleaning the casing Stainless steel colored controlsGrease filters Active charcoal filter Insert the charcoal filterChanging the light bulb After Sales Service Page Installation instructions Air extraction Disposal of packing material Caring for the environmentDisposal of an old appliance Installation accessories Installation instruction sheet Diverter recirculation mode onlyReducing collar To install a plywood backing Plywood backingElectrical data This Appliance Must be GroundedAppliance dimensions Appliance dimensions Dismantling InstallationInstallation instruction Protective filmAir extraction Condensate trap Page Alteration rights reserved