Miele DA5190W Grease filter timer, Charcoal filter timer, Checking the filter timer

Page 14

Operation

Grease filter timer

A timer monitors the hours of fan operation. The indicator for the grease/charcoal filter will light red after 30 hours of operation or the preselected time. The grease filter must then be cleaned. See "Cleaning and Care/Grease filter".

After the grease filter has been cleaned and put in place, the grease filter timer must be reset.

^To do this, press the grease/charcoal filter button for about 3 seconds while the fan is running.

The indicator will go out.

Charcoal filter timer

Recirculation mode only

The timer for the charcoal filter is not preset. Please program this timer, see "Operation/Reprogramming the charcoal filter timer".

The charcoal filter indicator will light blue once the selected time has elapsed. The charcoal filter must then be replaced and the timer reset.

^To do this, press the grease/charcoal filter button for about 3 seconds.

The indicator will go out.

Checking the filter timer

To check the percentage of time already used:

^Press the On/Off button to turn the fan on.

For the grease filter timer

^Press and hold the grease/charcoal filter button. The indicator lights red.

For the charcoal filter timer

^Press the grease/charcoal filter button twice and hold. The indicator lights blue.

The number of flashing "–/+" indicators show the percentage of programmed hours that have been used.

1 indicator = 25 %

2 indicators = 50 %

3 indicators = 75 %

4 indicators = 100 %

This information will remain stored in memory in the event of a power failure.

14

Image 14
Contents En US, CA Contents Important Safety Instructions Use Evacuate and Call the Fire Department Only ifInstallation To reduce the risk of fire only use metal ductworkAir extraction Recirculation modeFunctional description Guide to the hood Grease filter Light button On/Off button Fan power selection Delayed shut downActive Charcoal Filter Grease and charcoal filter buttonAutomatically switching back the intensive power level Selecting the power levelIntensive setting OperationFan performance Automatic Safety Shut Off Turning off the fanTurning the lighting on/off Dimming the lightingChecking the filter timer Grease filter timerCharcoal filter timer For the grease filter timerReprogramming the grease filter timer Reprogramming the charcoal filter timer Stainless steel Cleaning and CareCleaning the casing Stainless steel colored controlsGrease filter Removing the grease filterCleaning the grease filter Active charcoal filter Changing the light bulb MieleCare After Sales ServiceRepairs Http//store.miele.comInstallation Instructions Page Disposal of an old appliance Caring for the environmentDisposal of packing material Installation accessories Telescopic retaining plate secures the chimney extension Protective shieldsReducing collar Large headed screws 5 x 40 mmTo install a plywood backing Plywood backingElectrical data Grounding InstructionsAppliance dimensions For recirculation mode only 4 and only outlet installationDistance between cooktop and hood S Standard unit height HProtective film InstallationInstallation instructions DismantlingAir extraction Condensate trap