Plywood backing

The majority of the weight of the installed ventilation system will be supported by the lower retaining plate. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the required locations, a plywood backing (min. ½" (13 mm) thick) spanning at least two studs must be installed. Failure to adequately support the weight as stated may result in the ventilation system falling off the wall, causing personal injury and property damage.

(If plywood backing is not needed, proceed to the included installation sheet.)

To install a plywood backing

^Determine and mark the location of the retaining plate for the canopy as outlined on the installation sheet.

^Make a cutting line 3" (76 mm) above and 3" (76 mm) below the outline of the retaining plate.

^Find the studs to the left and right of the mounting location by tapping the wall or using a stud finder.

^Mark a vertical cutting line along the center of each stud.

Be careful not to damage any wiring or plumbing that may be located behind the wall. Make sure that the power supply to the area where this installation is being performed has been turned off at the breaker panel before cutting into the wall.

^Remove the drywall between the cutting lines and replace it with plywood of a matching thickness (min. ½" (13 mm) thick). Tape the joints and refinish the wall.

^Proceed to the included installation sheet to complete the installation.

28

Image 28
Contents En US, CA Contents Important Safety Instructions Use Evacuate and Call the Fire Department Only ifInstallation To reduce the risk of fire only use metal ductworkFunctional description Recirculation modeAir extraction Guide to the hood On/Off button Fan power selection Delayed shut down Active Charcoal FilterGrease filter Light button Grease and charcoal filter buttonSelecting the power level Intensive settingAutomatically switching back the intensive power level OperationFan performance Automatic Safety Shut Off Turning off the fanTurning the lighting on/off Dimming the lightingGrease filter timer Charcoal filter timerChecking the filter timer For the grease filter timerReprogramming the grease filter timer Reprogramming the charcoal filter timer Cleaning and Care Cleaning the casingStainless steel Stainless steel colored controlsGrease filter Removing the grease filterCleaning the grease filter Active charcoal filter Changing the light bulb After Sales Service RepairsMieleCare Http//store.miele.comInstallation Instructions Page Disposal of packing material Caring for the environmentDisposal of an old appliance Installation accessories Protective shields Reducing collarTelescopic retaining plate secures the chimney extension Large headed screws 5 x 40 mmTo install a plywood backing Plywood backingElectrical data Grounding InstructionsAppliance dimensions For recirculation mode only 4 and only outlet installationDistance between cooktop and hood S Standard unit height HInstallation Installation instructionsProtective film DismantlingAir extraction Condensate trap