Air extraction

,WARNING

Danger of toxic fumes.

Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled.

The exhaust gases extracted by the hood should be vented outside of the building only.

Do not terminate the exhaust ducts in attics, garages, crawlspaces, etc.

To reduce the risk of fire, only use metal ductwork.

Please read and follow the

"IMPORTANT SAFETY INSTRUCTIONS" to reduce the risk of personal injury. Follow all local building codes when installing the hood.

Exhaust ducting and connections

The ducting should be as short and straight as possible, and the number of sharp bends should be minimized.

For most efficient air extraction, the diameter of the ductwork should not be less than 6" (150 mm). Use of flat ducts also reduces the air extraction efficiency.

Noise levels of the hood will increase if flat ducts or round ducts of less than 6" (150 mm) in diameter are used.

Use smooth or flexible pipes made from approved non-flammable materials for exhaust ducting.

Where the ductwork is horizontal, it

must slope away from the hood at least 1/8" per foot (1 cm per meter) to prevent condensation dripping into the appliance.

If the exhaust is ducted through an outside wall, a Miele Telescopic Wall Vent can be used.

33

Image 33
Contents En US, CA Contents Important Safety Instructions Use Only if Evacuate and Call the Fire DepartmentTo reduce the risk of fire only use metal ductwork InstallationRecirculation mode Functional descriptionAir extraction Guide to the hood Active Charcoal Filter On/Off button Fan power selection Delayed shut downGrease filter Light button Grease and charcoal filter buttonIntensive setting Selecting the power levelAutomatically switching back the intensive power level OperationFan performance Turning off the fan Automatic Safety Shut OffDimming the lighting Turning the lighting on/offCharcoal filter timer Grease filter timerChecking the filter timer For the grease filter timerReprogramming the grease filter timer Reprogramming the charcoal filter timer Cleaning the casing Cleaning and CareStainless steel Stainless steel colored controlsRemoving the grease filter Grease filterCleaning the grease filter Active charcoal filter Changing the light bulb Repairs After Sales ServiceMieleCare Http//store.miele.comInstallation Instructions Page Caring for the environment Disposal of packing materialDisposal of an old appliance Installation accessories Reducing collar Protective shieldsTelescopic retaining plate secures the chimney extension Large headed screws 5 x 40 mmPlywood backing To install a plywood backingGrounding Instructions Electrical dataFor recirculation mode only 4 and only outlet installation Appliance dimensionsStandard unit height H Distance between cooktop and hood SInstallation instructions InstallationProtective film DismantlingAir extraction Condensate trap