Miele DA5190W Installation, To reduce the risk of fire only use metal ductwork

Page 6

IMPORTANT SAFETY INSTRUCTIONS

Installation

~, WARNING

To reduce the risk of fire only use metal ductwork.

~Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum safety distances between a cooktop and the bottom of the hood:

22" (550 mm) above electric cooktops,

30" (762 mm) above gas cooktops,

26" (650 mm) above an open electric grill or an open electric boiler/fryer.

If local building codes require a greater safety distance, follow their requirement.

If there is more than one appliance beneath the hood and they have different minimum safety distances always select the greater distance.

~Be careful not to damage hidden electrical wiring or plumbing when cutting or drilling into the wall or ceiling.

~Do not use an extension cord to connect the appliance to electricity. Extension cords do not guarantee the required safety of the appliance, (e.g. danger of overheating).

~Do not install this hood over cooktops burning solid fuel.

~Any fittings, sealant, or materials used to install the ductwork must be made of approved non-flammable materials.

~Never connect an exhaust hood to an active chimney, dryer vent, vent flue, or room ventilating ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent flue.

~Ducted fans must always be vented outdoors.

~Make sure that the airflow in the room is sufficient for combustion and exhausting of all non-electric heating appliances (water heaters, gas cooktops, gas ovens, etc.), otherwise backdrafts may occur. Follow the heating manufacturer’s guidelines and safety standards or those published by the National Fire Protection Association (NFPA) or the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE).

If in doubt, consult an experienced professional.

6

Image 6
Contents En US, CA Contents Important Safety Instructions Use Evacuate and Call the Fire Department Only ifInstallation To reduce the risk of fire only use metal ductworkRecirculation mode Functional descriptionAir extraction Guide to the hood Grease filter Light button On/Off button Fan power selection Delayed shut downActive Charcoal Filter Grease and charcoal filter buttonAutomatically switching back the intensive power level Selecting the power levelIntensive setting OperationFan performance Automatic Safety Shut Off Turning off the fanTurning the lighting on/off Dimming the lightingChecking the filter timer Grease filter timerCharcoal filter timer For the grease filter timerReprogramming the grease filter timer Reprogramming the charcoal filter timer Stainless steel Cleaning and CareCleaning the casing Stainless steel colored controlsGrease filter Removing the grease filterCleaning the grease filter Active charcoal filter Changing the light bulb MieleCare After Sales ServiceRepairs Http//store.miele.comInstallation Instructions Page Caring for the environment Disposal of packing materialDisposal of an old appliance Installation accessories Telescopic retaining plate secures the chimney extension Protective shieldsReducing collar Large headed screws 5 x 40 mmTo install a plywood backing Plywood backingElectrical data Grounding InstructionsAppliance dimensions For recirculation mode only 4 and only outlet installationDistance between cooktop and hood S Standard unit height HProtective film InstallationInstallation instructions DismantlingAir extraction Condensate trap