Miele 09 824 260 installation instructions Plywood backing, To install a plywood backing

Page 26

Plywood backing

The majority of the weight of the installed ventilation system will be supported by the retaining plate. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the required locations, a plywood backing (min. ½" (13 mm) thick) spanning at least two studs must be installed. Failure to adequately support the weight as stated may result in the ventilation system falling off the wall, causing personal injury and property damage.

(If plywood backing is not needed, proceed to the included "Installation diagram".)

To install a plywood backing

￿Determine and mark the location for the canopy as outlined in "Appliance dimensions".

￿Make a cutting line 3" (76 mm) above and 3" (76 mm) below the outline of the retaining plate.

￿Find the studs to the left and right of the mounting location by tapping the wall or using a stud finder.

￿Mark a vertical cutting line along the center of each stud.

￿CAUTION

When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utilities.

￿Remove the drywall between the cutting lines and replace it with plywood of a matching thickness (min. ½" (13 mm) thick). Tape the joints and refinish the wall.

￿Proceed to the enclosed "Installation diagram" to complete the installation.

26

Image 26
Contents Operating and Installation Instructions Ventilation System Contents Important Safety Instructions Use To Reduce the Risk of a Cooktop Grease FireEvacuate and Call the Fire Department Installation Air extraction with internal blower Air recirculation modeDescription of functions Air extraction with external blowerGuide to the Ventilation System On/Off switch plus 4 fan speeds Following combinations of appliances are possible Turning the light on/off Selecting the blower power levelOperation Turning the blower on/offSpecial instructions for stainless steel surfaces Cleaning and CareCleaning the casing Baffle filtration Stainless steel colored controlsCleaning and Care OdorFree charcoal filters Replacing the OdorFree charcoal filtersMieleCare After Sales ServiceRepairs Installation Instructions Disposal of an old appliance Caring for the environmentDisposal of packing material Appliance dimensions Appliance dimensions Appliance dimensions Appliance dimensions Appliance dimensions Distance between cooktop and hood S Appliance dimensions To install a plywood backing Plywood backingProtective film InstallationInstallation instructions Air extraction Air extraction Electrical connection Grounding InstructionsTechnical data Page Page Page Page DAR 1120, 1130 DAR 1220, 1230 En US, CA Nr 824 260