Vulcan-Hart GR85F ML-135535, GRD85F ML-126741, GR35F ML-126998 Turn the filter power switch on Fig

Page 9

3.While holding the discard hose at the base of the fitting, use your free hand to slide the collar away from the end of the female fitting (Fig. 12). Align the male and female parts of the quick disconnect line and push the hose onto the male connector discharge fitting. Release the collar. Pull the discharge hose away from the fryer to make sure discharge hose is fully inserted and locked.

 

PL-41613

 

Gas Fryer

 

Electric Fryer

 

 

Fig. 12

PL-41614

4. Turn the filter power switch ON (Fig. 13).

 

PL-41615

 

Gas Fryer

 

Electric Fryer

 

 

Fig. 13

PL-41616

5.Place the nozzle in a suitable discharge container. To start the pump, pull the white discard valve handle out (Fig. 14); the oil begins to flow through the discard hose. If the discharge container is not large enough for the entire amount, stop the pump by pushing in the white discard valve handle, empty the container and resume. When the last of the oil is in the discharge container, stop the pump by pushing in the white discard valve handle, turn the filter power switch OFF and disconnect the discharge hose (Fig. 15).

6.Clean the filter drawer following the instructions on page 10.

PL-41617

PL-41618

Fig. 14

Fig. 15

– 9 –

Image 9
Contents Kleenscreen Filtration System Table of Contents General AssemblyControls and Component Locations Gas Fryers Controls and Component Locations Electric Fryers Operation Filtering Procedure When Using Liquid ShorteningFiltering Procedure When Using Solid Shortening Filtering Tips Periodically Remove Excess Debris from the FilterFlush and Discard Turn the filter power switch on Fig Cleaning the Filter Drawer MaintenanceFryer BOIL-OUT Instructions Service Troubleshooting