Vulcan-Hart GRC65F ML-126739, GRD85F ML-126741, GRD45F ML-126735 Troubleshooting, Service

Page 12

18.After rinsing the tank, close the drain valve and refill the tank with hot water to the - Max - fill line.

19.Add 1 cup (0.2 L) of vinegar per 20 lb (9 kg) of fryer capacity to neutralize any caustic ingredients remaining from the boil-out solution.

20.Turn the fryer on and slow boil for a few minutes with the thermostat set at 210°F to 225°F (99°C to 107°C).

21.Turn the fryer off and drain the tank (see steps 14 and 15).

22.Close the drain valve and rinse the tank again with hot water.

23.Drain fryer tank (see steps 14 and 15) and remove. Dry and reassemble the filter screen assembly. Thoroughly dry the fryer tank. Close the drain valve. Reinstall the entire filter drawer assembly to the fryer. Fill the tank to the - Min - fill line with fresh oil or shortening.

TROUBLESHOOTING

NOTE: If using solid shortening, after all filtered oil has been returned to the fryer tank and the filter power switch is off, open the filter drawer approximately 1 inch. This allows the remaining shortening in the line to drain into the filter tank to prevent possible clogging as the shortening cools and solidifies.

SYMPTOM

 

POSSIBLE CAUSE

 

SUGGESTED CORRECTIVE ACTION

 

 

 

 

 

Oil not

1.

Drawer not closed all the way.

1.

Close the drawer.

filtering or

2. Filter screen is plugged.

2.

Clean filter screen.

discarding;

3.

Clog in filter system line(s).

3.

Call service.

pump motor

4. Shortening is below 300°F (149°C) and too thick.

4. Increase temperature above 300°F (149°C).

is on.

5.

Mechanical problem with return or discard valve.

5.

Call service.

 

6.

Pump is inoperative.

6.

Call service.

 

7. Discard hose connection not fully engaged.

7. Remove and reconnect the hose.

 

 

 

Pump motor

1. Check 120 V power connection.

1. Plug unit into 120 V receptacle.

is not

2.

Filter power switch is not turned on.

2.

Turn switch on.

running.

3.

Discard valve handle is not extended.

3.

Pull out discard valve handle.

 

4.

Pump motor not working.

4.

Call service.

 

 

 

 

 

SERVICE

Contact your local Vulcan Service Office for any repairs or adjustments needed on this equipment.

FORM 35616 (Nov. 2003)

– 12 –

PRINTED IN U.S.A.

Image 12
Contents Kleenscreen Filtration System Table of Contents Assembly GeneralControls and Component Locations Gas Fryers Controls and Component Locations Electric Fryers Filtering Procedure When Using Liquid Shortening OperationFiltering Procedure When Using Solid Shortening Filtering Tips Periodically Remove Excess Debris from the FilterFlush and Discard Turn the filter power switch on Fig Maintenance Cleaning the Filter DrawerFryer BOIL-OUT Instructions Troubleshooting Service