Vulcan-Hart 1GR85DF ML-136790, 3GR45DF ML-136427 manual Do not Wash Fabric Envelope, Step

Page 20

GRDF / GRCF SERIES GAS FRYERS

INSTRUCTIONS TO REMOVE & REPLACE KLEENSCREEN PLUS® FILTER ENVELOPE

FOR ABSOLUTE FILTRATION & MAXIMUM FLOW RATE WE RECOMMEND YOU CHANGE YOUR FILTER ENVELOPES AT EVERY OIL CHANGE (10-14 DAYS DEPENDING ON OIL USAGE).

Step 1

Discard all oil from the filter vessel, (see pages 23 or 24). When the filter pan is empty, use a spatula and scrape off all debris left on the filter envelope and in the filter pan.

Step 2

Unscrew “S” Tube from filter by turning the Bottom Knurled fitting counter- clockwise.

Step 3

Remove SST Closure Clip by lifting off one side.

Step 4

Remove SST Filter Screen Insert and wash insert with hot water and dry thoroughly. The Filter Screen Insert is dishwasher safe. Place the insert into a new KleenScreen PLUS® Filter envelope.

DO NOT WASH FABRIC ENVELOPE

Step 5

Place Filter Screen Insert into the fabric envelope making sure that the holes line up. Fold over the other end of the envelope and place SST Closure Clip on – hinge over and firmly press clip all the way down to secure and seal filter assembly. Making sure that the folded end is face down; screw “S” Tube Assembly onto the Filter Assembly. Tighten the Bottom Knurled fitting. When tightened, the “S” Tube assembly should be perpendicular to the long side of the filter assembly.

Step 6

Reposition the filter tube into the provided clip. Align filter tube so that the end of the “S” Tube engages the Oil Receptacle fitting each time the drawer is opened and closed.

VULCAN-HART

F-32933 Rev. G (May 2009)

-20-

Image 20
Contents Installation & Operational Manual Important for Your Safety Table of Contents Introduction Ordering PartsUnpacking GeneralLocation InstallationFryer Model No Device Serial No Clearances Assembly Codes and StandardsUnited States CanadaUse soap and water solution. Do not use an open flame Flue ConnectionElectrical Connection GAS ConnectionFryers with Casters Testing the GAS Supply Piping SystemGAS Pressures ALL Models Operation OVER-TEMPERATURE ShutdownLeveling the Fryer Filling Tank with Shortening CleaningBefore First USE Basic Frying Instruction Extending Shortening LifeFry Basket Guidelines Fry Basket CapacityFiltering the OIL Turning on the FryerExtended Shutdown Programming the Solid State Control Programming the Computer Control Draining the Tank Boil OUT ProcedureWeekly or when oil is replaced Cleaning GAS KleenScreen Plus Models 2GR45DF ShownFiltering Instructions for KleenScreen Plus Fryers Same Suction Tube Do not Wash Fabric Envelope StepFiltering Procedure OperationGrdf / Grcf Series GAS Fryers Grdf / Grcf Series GAS Fryers Flush and Discard Filtering TIPRemoving Excess Debris from the Screen Filter Boil OUT Procedure Thermal Overload Protection ButtonMaintenance Alarms and Error MessagesService in the US and Canada Flue Vent InspectionTroubleshooting Chart

1GR65CF ML-136792, 1GR65C ML-136415, 1GR65D ML-136412, 1GR45C ML-136414, 1GR45CF ML-136791 specifications

Vulcan-Hart is a revered name in the foodservice equipment industry, known for its innovation and reliability. Among its impressive offerings are several models, including the 3GR45DF ML-136427, 2GR45DF ML-136424, 2GR45CF ML-136431, 1GR85D ML-136413, and 1GR85CF ML-136793. These models are designed to meet the high demands of commercial kitchens, providing versatile solutions that prioritize efficiency and performance.

The 3GR45DF ML-136427 is a robust unit featuring three well-designed griddles, allowing multiple cooking tasks to be handled simultaneously. This model is equipped with an advanced temperature control system that ensures even heating and quick recovery times, assisting chefs in delivering quality dishes consistently. The stainless steel construction not only enhances durability but also provides ease of cleaning, maintaining the hygiene standards expected in foodservice operations.

The 2GR45DF ML-136424 offers similar features, with two griddles ideal for establishments with moderate cooking needs. It includes a heavy-duty grease drawer for easy disposal, while the adjustable legs ensure stability on various surfaces. This model integrates energy-efficient technologies, reducing overall operating costs without compromising performance.

For establishments that prioritize versatility, the 2GR45CF ML-136431 introduces a combination of griddle and charbroiler spaces, enabling chefs to explore a broader culinary range. Its innovative design allows for seamless transitions between cooking styles, catering to diverse customer preferences. The charbroiler features an adjustable air shutter for optimal flame control, delivering a perfect sear every time.

The 1GR85D ML-136413 and 1GR85CF ML-136793 models are tailored for kitchens with space limitations but still require high-functionality appliances. The 1GR85D features a single robust griddle ideal for smaller operations, while the 1GR85CF combines griddle and charbroiler capabilities in a compact footprint. Both models retain high-efficiency elements and user-friendly controls, making them invaluable assets for fast-paced environments.

Each of these Vulcan-Hart units is designed with user safety in mind, including features such as cool-to-the-touch handles and safety shut-off mechanisms. The emphasis on cutting-edge technology, such as electronic ignition systems and precise temperature regulators, ensures that operational efficiency is never compromised. With Vulcan-Hart's commitment to quality and innovation, these models are pillars of excellence in any commercial kitchen setting.