ELECTRIC STATIONARY KETTLES |
|
PLUG VALVE CLEAINING | NOTE: 1. Care should be taken not to |
INSTRUCTIONS | scratch, ding or dent the valve |
| plug to prevent valve leakage. |
Daily Before Operation
Install draw off valve plug:
1.Apply PetroGel lubricant to valve tapered face.
2.Holding the valve handle, slide the plug down into the valve body.
3.Install the bottom washer, making sure to align the key with the groove in the valve plug.
4.Install the retaining ring and hand tighten.
NOTE: If the valve is hard to open the ring has been overtightened.
Daily After Use
Remove
1.Unscrew the retaining ring and remove it and the bottom washer.
2.Pull the valve plug straight up to remove from valve body.
3.Wash valve body, plug, washer and retaining ring with mild soap and water.
4.Leave assembly apart to air dry.
2.If multiple kettles are in use care should be taken keep each plug separate and returned to its original valve body.
Valve Plug
Valve Body
Bottom Washer
Retaining Ring
Fig. 7 Plug Valve
— 10 —