Reference Manual
00809-0100-4663, Rev BA
January 2010
Rosemount 8732
E-12
Model 10D1430 Sensor (Integral) to Rosemount 8732
Transmitter

Connect coil drive and electrode cables as shown in Figure E-9.

Figure E-9. Wiring Diagram for

Fischer and Porter Sensor

Model 10D1430 (Integral) and

Rosemount 8732

Table E-10. Fischer and Porter

Model 10D1430 (Integral)

Sensor Wiring Connections

Electrode Connections ROSEMOUNT 8732 TRANSMITTER
To L2
1
2
3
7
6
8
L2
L1
U2
U1
1
2
3
7
6
L2
L1
U2
U1
G
TB1
TB2
Coil Connections
To Calibration Device
(Disconnect)
Rosemount 8732 Fischer and Porter Model 10D1430 (Integral)
Sensors
1L1
2L2
G
17 3
18 1
19 2
This is a pulsed DC magnetic flowmeter.
Do not connect AC power to the sensor
or to terminals 1 and 2 of the
transmitter, or replacement of the
electronics board will be necessary.