Rosemount 8732

Reference Manual

00809-0100-4663, Rev BA January 2010

YAMATAKE HONEYWELL SENSORS

Yamatake Honeywell Sensor to Rosemount 8732 Transmitter

Figure E-21. Generic Wiring Diagram for Yamatake Honeywell Sensors and Rosemount 8732

Connect coil drive and electrode cables as shown in Figure E-21.

YAMATAKE

ROSEMOUNT 8732

HONEYWELL

TRANSMITTER

SENSORS

 

Electrodes

A

B

 

 

C

Chassis Ground

Coils

Y

 

X

 

Fuse

Table E-22. Yamatake

Honeywell Sensor Wiring

Connections

Rosemount 8732

 

Yamatake Honeywell Sensors

1

 

 

 

X

2

 

 

 

Y

 

 

 

 

 

 

Chassis Ground

 

 

 

 

 

17

 

 

C

18

 

 

B

19

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This is a pulsed DC magnetic flowmeter.

Do not connect AC power to the sensor or to terminals 1 and 2 of the transmitter, or replacement of the electronics board will be necessary.

E-24

Page 164
Image 164
Emerson Process Management manual Yamatake Honeywell Sensors, Yamatake Honeywell Sensor to Rosemount 8732 Transmitter